Z1: NC/PLC interface signals
19.6 Mode group, channel, program operation, reset response
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
1693
DB31, ...
DBX70.1
REPOS offset valid
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The range of validity of the REPOS offset is indicated with the value 1.
The REPOS offset was calculated to be valid.
Signal state 0 or
edge change
1 → 0
A value of zero indicates that the REPOS offset was calculated to be invalid.
Application
example(s)
Updating the REPOS offset in the range of validity:
Between SERUPRO end and start, the axis can be moved in JOG mode with a mode change. The
user moves the REPOS offset to the zero value.
Corresponds to ....
DB31, ... DBX70.0 (REPOS offset)
DB31, ...
DBX70.2
REPOS Delay Ackn
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
The axis was programmed within a traversing block, and the REPOS offset was applied.
Note
A REPOS offset was available for the axis, and REPOSDELAY was active:
DB31, ... DBX10.0 (REPOSDELAY) == 1
This signal behaves the same as:
DB21, ... DBX319.1 - DBX319.3 (Repos Path Mode Ackn)
Signal state 0 or
edge change
1 → 0
The value zero is used to acknowledge that the REPOS offset is not active for this axis. This signal
is cancelled on activation of the remaining block.
Corresponds to ....
DB31, ... DBX10.0 (REPOSDELAY)
DB31, ... DBX72.0 (REPOSDELAY)
DB31, ...
DBX72.0
REPOSDELAY
Edge evaluation: no
Signal(s) updated: cyclic
Signal state 1 or
edge change
0 → 1
After a block search, a REPOS offset is applied for this axis. However it is not applied using the
approach block, but rather using the next traversing block in which the axis is programmed.
Signal state 0 or
edge change
1 → 0
The REPOS offset for this axis is not active.
Special cases,
errors, ......
The signal is not relevant for path axes.
Corresponds to ....
DB21, ... DBX31.0 - DBX31.2 (REPOSPATHMODE)
DB31, ... DBX10.0 (REPOSDELAY)
DB31, ... DBX70.2 (REPOS Delay Ackn)
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...