7.7.3.2
X2 PROFINET
Requirement
The I/O module has certified PROFINET interfaces, however their functionality cannot be fully
utilized within the scope of the SINUMERIK 828D control system. Networking within
SINUMERIK 828D is performed via a PLC I/O interface, which is based on PROFINET.
Data Transmission Rate and Cables
The interfaces are designed for full-duplex mode; in other words, the ports can both transmit
and receive. When connecting I/O modules to the SINUMERIK 828D, please use the
preassembled SINAMICS DRIVE-CLiQ signal cables; from a technical point of view, these are
also suitable for use with PROFINET:
● Article number: 6FX2002-1DC00-...
● The transmission characteristics of these cables meet the requirements of CAT5.
● Data transmission speed: 100 Mbps (fast Ethernet).
● The maximum length of the connections between the end device and network component
or between two network components (e.g. switch ports) must not exceed 70 m.
Pin assignment
Table 7-85
Pin assignment - PROFINET X2, Port 1 and Port 2
Pin
Signal name
Signal type
Meaning
1
TX+
O
Transmit data +
2
TX-
O
Transmit data -
3
RX+
I
Receive data +
4
N.C.
-
Not assigned
5
N.C.
-
Not assigned
6
RX-
I
Receive data -
7
N.C.
-
Not assigned
8
N.C.
-
Not assigned
LED displays
For diagnostic purposes, the RJ45 sockets are each equipped with a green and a yellow LED.
This allows the following information on the respective PROFINET port to be displayed:
Table 7-86
PROFINET ports LED displays
Name
Color
Status
Meaning
Link
Green
Lit
100 Mbit link available
Off
Missing or faulty link
Connectable components
7.7 PP 72/48D 2/2A PN
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
193
Содержание SINUMERIK 828D PPU Series
Страница 12: ......
Страница 34: ......
Страница 42: ......
Страница 52: ......
Страница 92: ......
Страница 150: ... r r r Connectable components 7 4 Electronic handwheel PPU 150 Manual 01 2014 6FC5397 2DP40 3BA3 ...
Страница 224: ......
Страница 226: ......
Страница 240: ......
Страница 244: ......