Task navigation
SINAMICS V-ASSISTANT Online Help
118
Operating Manual, 04/2017, A5E36618042-003
●
p29111
●
p29120[0]
●
p29121[0]
Resonance suppression with manual tuning (p29021=0)
When both the resonance suppression with real-time auto tuning and one-button tuning
mode cannot reach the suppression effect, you can do the resonance suppression by
manually setting the following parameters:
Parame-
ter
Value range Default
value
Unit Description
p1663
0.5 to 16000 1000
Hz
Natural frequency of current notch filter 2 denominator.
p1664
0.001 to 10 0.3
-
Damp of current notch filter 2 denominator.
p1665
0.5 to 16000 1000
Hz
Natural frequency of current notch filter 2 numerator.
p1666
0.0 to 10
0.01
-
Damp of current notch filter 2 numerator.
p1668
0.5 to 16000 1000
Hz
Natural frequency of current notch filter 3 denominator.
p1669
0.001 to 10 0.3
-
Damp of current notch filter 3 denominator.
p1670
0.5 to 16000 1000
Hz
Natural frequency of current notch filter 3 numerator.
p1671
0.0 to 10
0.01
-
Damp of current notch filter 3 numerator.
p1673
0.5 to 16000 1000
Hz
Natural frequency of current notch filter 4 denominator.
p1674
0.001 to 10 0.3
-
Damp of current notch filter 4 denominator.
p1675
0.5 to 16000 1000
Hz- Natural frequency of current notch filter 4 numerator.
p1676
0.0 to 10
0.01
-
Damp of current notch filter 4 numerator.
Assume the notch frequency is f
sp
, notch width is f
BB
, and notch depth is K, then the filter
parameters can be calculated as follows:
p1663=p1665=f
sp
p1664=f
BB
/ (2 × f
sp
)
p1666=(f
BB
× 10
(k/20)
)/ (2 × f
sp
)
Содержание SINAMICS V90
Страница 4: ...Preface SINAMICS V ASSISTANT Online Help 4 Operating Manual 04 2017 A5E36618042 003 ...
Страница 8: ...Table of contents SINAMICS V ASSISTANT Online Help 8 Operating Manual 04 2017 A5E36618042 003 ...
Страница 156: ...Task navigation SINAMICS V ASSISTANT Online Help 156 Operating Manual 04 2017 A5E36618042 003 ...