9.5.1.2
Replacing fans, from the back
Removing the fan
The five safety rules must be observed.
Figure 9-3
Schematic diagram: Replacing fans from the back
1. Remove the rear cover from the fan box
②
.
2. Loosen the connector of the fan connector cable from the terminal in the fan box.
3. Loosen the fastening screws of fan
③
.
4. Pull the fan out of the fan box.
5. Release the connecting cable
①
at the fan.
6. Remove the two sheet metal brackets
④
from the fan baseplate.
CAUTION
The fan can fall
The fans are very heavy. They can cause injury or material damage if handled improperly.
Please take special care when removing the fans from the drive.
Installing the fan
Install the fan in reverse order.
Maintenance
9.5 Maintenance
SINAMICS SH150 6SL3805
96
Operating Instructions 05/2020
Содержание SINAMICS SH150
Страница 2: ...19 06 2020 09 42 V14 00 ...
Страница 12: ...Introduction 1 1 About these instructions SINAMICS SH150 6SL3805 12 Operating Instructions 05 2020 ...
Страница 42: ...Description 3 9 Interfaces SINAMICS SH150 6SL3805 42 Operating Instructions 05 2020 ...
Страница 56: ...Preparations for use 4 5 Storage SINAMICS SH150 6SL3805 56 Operating Instructions 05 2020 ...
Страница 116: ...Spare parts SINAMICS SH150 6SL3805 116 Operating Instructions 05 2020 ...
Страница 120: ...Service Support SINAMICS SH150 6SL3805 120 Operating Instructions 05 2020 ...
Страница 124: ...Technical data and drawings B 2 Environmental conditions SINAMICS SH150 6SL3805 124 Operating Instructions 05 2020 ...
Страница 126: ...Quality documents SINAMICS SH150 6SL3805 126 Operating Instructions 05 2020 ...
Страница 128: ...Additional documents SINAMICS SH150 6SL3805 128 Operating Instructions 05 2020 ...
Страница 131: ......
Страница 132: ...Further Information www siemens com LDA Siemens AG Large Drives Applications Vogelweiherstr 1 15 90441 NÜRNBERG GERMANY ...