Operation
9.3 Controlling via the AOP30 operator panel
SINAMICS DCM DC Converter
386
Operating Instructions, 12/2018, A5E34763375A
Display diagnostics
When you navigate to the required line and
then press the F5 <OK> key, the correspond-
ing faults/alarms are displayed. The list of
current faults is selected here as an example.
Current faults display
A maximum of eight current faults are
displayed along with their fault number and a
description of the fault.
To display additional help regarding the cause
of the problem and how to solve it, choose F1
<Help>.
To acknowledge the faults, choose F5 <Ack>.
If a fault cannot be acknowledged, the fault
remains.
9.3.5
Menu: Commissioning/Service
9.3.5.1
Drive commissioning
Selecting this option enables you to re-commission the drive from the main menu, using the
AOP wizard.
Basic commissioning
A few key parameters (such as the maximum speed, ramp-up time, and ramp-down time)
are requested. The changes can then be permanently saved in the final confirmation screen.
Complete commissioning
Complete commissioning, with entry of the motor and encoder data, is carried out. Following
this, key motor parameters are recalculated on the basis of the motor data. The parameter
values calculated during the previous commissioning process are lost. The calculated values
are then overwritten during a subsequent optimization run.
Optimization run
The selection screen for the optimization runs appears.