s
Product information
A5E44420850 AB
Edition 07/2018
This product information is valid for operating instructions A5E41702836A AB,
Edition 07/2018
Erroneous display of message texts in the web server
In some messages, a reference to the List Manual erroneously appears. However, for S210, the
messages are integrated in the operating instructions.
You can find the corresponding explanation under the respective message number in the operating
instructions.
Designation of Safety messages in the operating instructions and web server
In the "Parameters" and "Faults and warnings" chapters of the operating instructions as well as in the
alarm descriptions in the web server, the messages are generally referred to as C0xxxx or C3xxxx.
The following list shows which messages are output as alarms and which as faults.
Alarm messages
C01706 ->
A01706
C01707 ->
A01707
C01709 ->
A01709
C01711 ->
A01711
C01714 ->
A01714
C01716 ->
A01716
C01730 ->
A01730
C01750 ->
A01750
C01751 ->
A01751
C01798 ->
A01798
C01799 ->
A01799
C30706 ->
A30706
C30707 ->
A30707
C30709 ->
A30709
C30711 ->
A30711
C30714 ->
A30714
C30716 ->
A30716
C30798 ->
A30798
C30799 ->
A30799
Fault messages
C01689 ->
F01689
C01700 ->
F01700
C01701 ->
F01701
C01708 ->
F01708
C30700 ->
F30700
C30701 ->
F30701
C30708 ->
F30708
Descriptions for the messages C01711 and C30711 in the web server
In the web server, an outdated description appears as the cause of these messages:
The current description for both messages is:
"The drive has issued message A01711/A30711 as a result of a discrepancy in the monitoring
channels." This means monitoring functions are no longer working reliably and safe operation is not
possible.
If a safety function is active, SS1 is triggered following expiration of the time set in p9555.
If no safety function is active, no stop reaction occurs. The message continues to be pending.
A full description can be found in the operating instructions.
SINAMICS S210 servo
drive system