6.3
Interface description
6.3.1
Overview
DRIVE-CLiQ Extension (DQE) has two connections for the S120M hybrid connector as well as
a connection for DRIVE-CLiQ.
The DRIVE-CLiQ signals of the incoming hybrid line are terminated and the DRIVE-CLiQ
signals of the DRIVE-CLiQ cable are fed into the new hybrid line. All other connections are only
looped through from the inputs to the outputs.
'5,9(&/L4
'4287
'42/'
;
287
,1
3(
3(
0
3
0
3
0
3
0
3
;
;
Figure 6-1
Block diagram of DRIVE-CLiQ Extension
Note
The X1 (input) and X2 (output) connections must not be interchanged.
6.3.2
Hybrid connector
Connecting the hybrid cable from the S120M of the previous line
Table 6-1
Terminal strip X1 (IN)
Terminal
Signal name
Technical data
1
1 (TXP)
Transmit data +
2
2 (RXP)
Receive data +
3
3 (TXN)
Transmit data -
4
4 (RXN)
Receive data -
5
PE
Potential equalization
6
M
Electronics ground
7
+
48 VDC power supply
8
DCN
DC link voltage - (M600)
9
DCP
DC link v (P600)
-
DQ_SHIELD
Shield
DRIVE-CLiQ Extension
6.3 Interface description
Manual, 06/2019, 6SL3097-5AW00-0BP1
111
Содержание Sinamics S120M
Страница 1: ...Equipment Manual Distributed drive technology Edition www siemens com drives 06 2019 S120M SINAMICS ...
Страница 2: ......
Страница 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 32: ...Fundamental safety instructions 2 4 Residual risks of power drive systems 30 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 185: ......