background image

 

 

 

 

Siemens AG 

Industry Sector 

Postfach 48 48 

90026 NÜRNBERG 

GERMANY 

A5E02914106A 

 09/2014 Subject to change 

Copyright © Siemens AG 2006 - 2014. 

All rights reserved 

Legal information 

Warning notice system 

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent 

damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert 

symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are 

graded according to the degree of danger. 

 

DANGER 

indicates that death or severe personal injury will result if proper precautions are not taken. 

 

 

WARNING 

indicates that death or severe personal injury may result if proper precautions are not taken. 

 

 

CAUTION 

indicates that minor personal injury can result if proper precautions are not taken. 

 

 

NOTICE 
indicates that property damage can result if proper precautions are not taken. 

If more than one degree of danger is present, the warning notice representing the highest degree of danger will 

be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to 

property damage. 

Qualified Personnel 

The product/system described in this documentation may be operated only by personnel qualified for the specific 

task in accordance with the relevant documentation, in particular its warning notices and safety instructions. 

Qualified personnel are those who, based on their training and experience, are capable of identifying risks and 

avoiding potential hazards when working with these products/systems. 

Proper use of Siemens products 

Note the following: 

 

WARNING 

Siemens products may only be used for the applications described in the catalog and in the relevant technical 

documentation. If products and components from other manufacturers are used, these must be recommended 

or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and 

maintenance are required to ensure that the products operate safely and without any problems. The permissible 

ambient conditions must be complied with. The information in the relevant documentation must be observed. 

Trademarks 

All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication 

may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. 

Disclaimer of Liability 

We have reviewed the contents of this publication to ensure consistency with the hardware and software 

described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the 

information in this publication is reviewed regularly and any necessary corrections are included in subsequent 

editions. 

Содержание SINAMICS S120

Страница 1: ......

Страница 2: ......

Страница 3: ...put side ___________________ ___________________ ___________________ SINAMICS S120 Cabinet Modules Option L34 parameterizing the circuit breaker on the output side Operating Instructions 04 2014 A5E02914106A Safety notes 1 Description 2 Operation software 3 ...

Страница 4: ...by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens product...

Страница 5: ...t breaker on the output side Operating Instructions 04 2014 A5E02914106A 5 Table of contents 1 Safety notes 7 1 1 General safety instructions 7 2 Description 11 3 Operation software 13 3 1 Handling instruction for execution of scripts 13 ...

Страница 6: ...Table of contents Option L34 parameterizing the circuit breaker on the output side 6 Operating Instructions 04 2014 A5E02914106A ...

Страница 7: ...d phase conductor to protective conductor Check that every auxiliary circuit is de energized Ensure that the motors cannot move 3 Identify all other dangerous energy sources e g compressed air hydraulic systems or water 4 Isolate or neutralize all hazardous energy sources by closing switches grounding or short circuiting or closing valves for example 5 Take measures to prevent reconnection of the ...

Страница 8: ...g or incorrectly implemented protective conductor connection for devices with protection class I high voltages can be present at open exposed parts which when touched can result in death or severe injury Ground the device in compliance with the applicable regulations WARNING Danger to life due to electric shock when opening plug connections in operation When opening plug connections in operation a...

Страница 9: ...l as a result of fire and smoke Use a monitoring device that signals an insulation fault Correct the fault as quickly as possible so the motor insulation is not stressed WARNING Danger to life due to fire if overheating occurs because of insufficient ventilation clearances Inadequate ventilation clearances can cause overheating with a risk for personnel as a result of fire and smoke This can also ...

Страница 10: ...nctions that are inactive or that have not been adjusted accordingly can cause operational faults on machines that could lead to serious injury or death Observe the information in the appropriate product documentation before commissioning Carry out a safety inspection for functions relevant to safety on the entire system including all safety related components Ensure that the safety functions used...

Страница 11: ...nual A script can be used for the automatic parameterization which automatically makes the parameter settings in STARTER For the automatic parameter setting of option L34 output side circuit breaker you will find the script output_side_circuit_breaker xml on the customer DVD supplied with the device To run the script the following steps must be completely carried out in the completed project Free ...

Страница 12: ...Description Option L34 parameterizing the circuit breaker on the output side 12 Operating Instructions 04 2014 A5E02914106A ...

Страница 13: ... software 3 3 1 Handling instruction for execution of scripts Inserting a script folder into the project 1 Right click the project in offline mode in the project navigator to open the project s context menu 2 Select Expert in the context menu 3 Left click Insert script folder to insert a new script folder into the project ...

Страница 14: ...tput side 14 Operating Instructions 04 2014 A5E02914106A Your inserted script folder should look like this Importing the script 1 Right click the SCRIPTS folder in the project navigator to open the context menu of the script folder 2 Left click Import object in the context menu of the script folder to open the Import window ...

Страница 15: ...window The Explorer window for the script import will open 4 Now select the path to the XML script from the customer DVD e g D 99 SOFTWARE SCRIPT_OptionL34 or to any memory location on your hard disk Left click the XML script output_side_circuit_breaker xml 5 Left click the Open button in the Explorer window to accept the path to the script 6 Left click the OK button in the Import window to import...

Страница 16: ...ted script should look like this Accepting and executing the script For the following steps you must have the project in online mode 1 Left click Connect to target system in the toolbar 2 Right click the script output_side_circuit_breaker in the project navigator to open the context menu of the script 3 Then left click Accept and execute in the context menu The script is saved and executed ...

Страница 17: ...e script is executing The user interface of the application is blocked while the script is executing Selecting the drive objects DO If several drive objects DO and or several input output components are available in the project e g Terminal Module TM31 you will be requested to select the desired object and or component 1 Select the desired drive object DO by entering the corresponding number 2 Con...

Страница 18: ...nt TM31 by entering the corresponding number 4 Confirm your selection with OK 5 Confirm your selection with OK when you have selected the correct drive object DO and or input output component TM31 6 If the report window appears showing Programming successful parameter assignment has been completed successfully Confirm with OK Note If the script has not been executed after approx 3 min cancel and r...

Страница 19: ......

Страница 20: ......

Отзывы: