Table 6-72
Pick list for Analog Output Variable Parameters
Motor Voltage
Neg Sequence Q
Out Neutral Volts
Analog Input #8
Total Current
Input Frequency
Synch Motor Field
Input KVAR
Average Power
Input Power Avg
Motor Torque
Drive Losses
Motor Speed
Input Pwr Factor
Encoder Speed
Excess React Current
Speed Demand
Ah Harmonic
Analog Input #1
Speed Droop Percent
Speed Reference
Bh Harmonic
Analog Input #2
Torq Current (Iqs) Ref
Raw Flux Demand
Total Harmonics
Analog Input #3
Torq Current (Iqs) Fb
Flux Reference
Xfmr Therm Level
Analog Input #4
Torq Current (IqsFilt) Filtered
Current (RMS)
1 Cycle Protect
Analog Input #5
Zero Sequence Av
Single Phase Cur
Analog Input #6
Neg Sequence D
Under Volt Limit
Analog Input #7
Table 6-73
Analog Output #1 Menu (4661)
Parameter
ID
Unit
De‐
fault
Min
Max
Description
Analog variable
4662
Set the input variable for analog output 1.
Output module type 4663
Set the output type for the module:
• unipolar
• bipolar
Full range
4664
%
0
0
300
Scale the output range of the selected variable.
Table 6-74
Speed Setpoint Menu (4240) Parameters*
Parameter
ID
Unit
De‐
fault
Min
Max
Description
Speed setpoint 1
4250
rpm
0
-18000
18000
Programmable speed setpoint
1
Speed setpoint 2
4260
rpm
0
-18000
18000
Programmable speed setpoint
1
Speed setpoint 3
4270
rpm
0
-18000
18000
Programmable speed setpoint
1
Speed setpoint 4
4280
rpm
0
-18000
18000
Programmable speed setpoint
1
Speed setpoint 5
4290
rpm
0
-18000
18000
Programmable speed setpoint
1
Speed setpoint 6
4300
rpm
0
-18000
18000
Programmable speed setpoint
1
Speed setpoint 7
4310
rpm
0
-18000
18000
Programmable speed setpoint
1
Speed setpoint 8
4320
rpm
0
-18000
18000
Programmable speed setpoint
1
Jog speed
4330
rpm
0
-18000
18000
Set the drive jog speed.
Safety setpoint
4340
rpm
0
-18000
18000
Safety override preset speed.
* Inputs are fixed in the command generator setpoint sources. Refer to Section Command
Generator in Chapter Operating the Control.
1
Can be selected through an external contact and the SOP.
Parameter Assignment/Addressing
6.11 Options for Auto Menu (4)
Control Manual
Operating Manual, A5E50491925A
145
Содержание SINAMICS PERFECT HARMONY GH180
Страница 2: ......
Страница 22: ...Table of contents NXGPro Control Manual 20 Operating Manual A5E50491925A ...
Страница 24: ...Security NXGPro Control Manual 22 Operating Manual A5E50491925A ...
Страница 504: ...NEMA Table NXGPro Control Manual 502 Operating Manual A5E50491925A ...
Страница 516: ...List of abbreviations C 1 Symbols and Abbreviations NXGPro Control Manual 514 Operating Manual A5E50491925A ...
Страница 517: ...Index D NXGPro Control Manual Operating Manual A5E50491925A 515 ...
Страница 518: ...Index NXGPro Control Manual 516 Operating Manual A5E50491925A ...
Страница 530: ...Glossary NXGPro Control Manual 528 Operating Manual A5E50491925A ...
Страница 537: ......
Страница 538: ... XUWKHU QIRUPDWLRQ ZZZ VLHPHQV FRP GULYHV 6LHPHQV QGXVWU QF 3 XQW 9DOOH 5RDG 1HZ HQVLQJWRQ 3 8QLWHG 6WDWHV RI PHULFD ...