Note
For p0651 = 0, the operating hours counter is disabled.
When setting p0651 to 0, then p0650 is automatically set to 0.
The operating hours counter only runs with drive data set 0 and 1 (DDS).
r0720[0...4]
CU number of inputs and outputs / CU I/O count
Access level: 3
Calculated: -
Data type: Unsigned16
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2119
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the number of inputs and outputs.
Index:
[0] = Number of digital inputs
[1] = Number of digital outputs
[2] = Number of digital input/outputs bidirectional
[3] = Number of analog inputs
[4] = Number of analog outputs
r0721
CU digital inputs terminal actual value / CU DI term act val
Access level: 2
Calculated: -
Data type: Unsigned32
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2201, 2221,
2256
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the actual value at the digital inputs.
This means that the actual input signal can be checked at terminal DI x or DI/DO x prior to switching from the simulation
mode (p0795.x = 1) to terminal mode (p0795.x = 0).
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (X133. 5)
High
Low
-
01
DI 1 (X133. 6)
High
Low
-
02
DI 2 (X133. 7)
High
Low
-
03
DI 3 (X133. 8)
High
Low
-
04
DI 4 (X133. 16)
High
Low
-
05
DI 5 (X133. 17)
High
Low
-
11
DI 11 (X131. 3, 4) AI 0
High
Low
-
12
DI 12 (X131. 10, 11) AI 1
High
Low
-
Note
AI: Analog Input
DI: Digital Input
r0722.0...12
CO/BO: CU digital inputs status / CU DI status
Access level: 2
Calculated: -
Data type: Unsigned32
Can be changed: -
Scaling: -
Dynamic index: -
Unit group: -
Unit selection: -
Function diagram: 2201, 2221,
2256
Min:
-
Max:
-
Factory setting:
-
Description:
Displays the status of the digital inputs.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
Parameters
7.3 Parameters
SINAMICS G120XA converter
426
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Содержание SINAMICS G120XA
Страница 2: ......
Страница 12: ...Table of contents SINAMICS G120XA converter 10 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 104: ...Wiring 4 2 Control interfaces SINAMICS G120XA converter 102 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 916: ...Index SINAMICS G120XA converter 914 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 917: ......