p2211[0...n]
CO: Technology controller fixed value 11 / Tec_ctr fix val 11
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: PERCENT
Dynamic index: DDS, p0180
Unit group: 9_1
Unit selection: p0595
Function diagram: 7950
Min:
-200.00 [%]
Max:
200.00 [%]
Factory setting:
110.00 [%]
Description:
Sets the value for fixed value 11 of the technology controller.
Dependency:
See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2212[0...n]
CO: Technology controller fixed value 12 / Tec_ctr fix val 12
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: PERCENT
Dynamic index: DDS, p0180
Unit group: 9_1
Unit selection: p0595
Function diagram: 7950
Min:
-200.00 [%]
Max:
200.00 [%]
Factory setting:
120.00 [%]
Description:
Sets the value for fixed value 12 of the technology controller.
Dependency:
See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2213[0...n]
CO: Technology controller fixed value 13 / Tec_ctr fix val 13
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: PERCENT
Dynamic index: DDS, p0180
Unit group: 9_1
Unit selection: p0595
Function diagram: 7950
Min:
-200.00 [%]
Max:
200.00 [%]
Factory setting:
130.00 [%]
Description:
Sets the value for fixed value 13 of the technology controller.
Dependency:
See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2214[0...n]
CO: Technology controller fixed value 14 / Tec_ctr fix val 14
Access level: 2
Calculated: -
Data type: FloatingPoint32
Can be changed: T, U
Scaling: PERCENT
Dynamic index: DDS, p0180
Unit group: 9_1
Unit selection: p0595
Function diagram: 7950
Min:
-200.00 [%]
Max:
200.00 [%]
Factory setting:
140.00 [%]
Description:
Sets the value for fixed value 14 of the technology controller.
Dependency:
See also: p2220, p2221, p2222, p2223, r2224, r2229
NOTICE
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Parameters
7.2 Parameter list
SINAMICS G120X converter
794
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......