Article number
Converter frame size Rated power (kW)
Line reactor
400 V converters
FSH
315
6SL3000-0CE36-3AA0
355 ... 400
6SL3000-0CE37-7AA0
FSJ
450
6SL3000-0CE38-7AA0
500 ... 560
6SL3000-0CE41-0AA0
690 V converters
FSH
315 ... 400
6SL3000-0CH34-8AA0
450
6SL3000-0CH36-0AA0
FSJ
500
560 ... 630
6SL3000-0CH38-4AA0
2.6.3
Line harmonics filter
Note
Line harmonics filters are available as optional components for 400 V converters of frame sizes
FSB to FSG.
The line harmonics filters reshape the distorted current back to the desired sinusoidal
waveform. With the line harmonics filters, the converter fulfills the IEEE 519 standards.
If you use a line harmonics filter, you do not need a line reactor or a line filter.
When using the line harmonics filter, observe the following restrictions:
● The permissible line voltage is 380 V ... 415 V 3 AC ±10 %.
● The operating frequency is 50 Hz.
For technical details refer to the following link:
https://www.schaffner.com/products/download/product/datasheet/
fn-3440-ecosine-50hz-passive-harmonic-filters/
)
Article number
400 V Converter
frame size
Rated power (kW)
Line harmonics filter
FSB
5.5
UAC:FN34406112E2XXJRX
7.5
UAC:FN34408112E2XXJRX
FSC
11
UAC:FN344011113E2FAJRX
15
UAC:FN344015113E2FAJRX
Description
2.6 Optional components
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
35
Содержание SINAMICS G120X
Страница 2: ......
Страница 152: ...Wiring 4 2 Control interfaces SINAMICS G120X converter 150 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 940: ...Parameters 7 3 ASCII table SINAMICS G120X converter 938 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1114: ...Appendix A 1 Manuals and technical support SINAMICS G120X converter 1112 Operating Instructions 06 2019 FW V1 01 A5E44751209B AC ...
Страница 1147: ......