background image

Assembling 

 

 

 

Mounting kit to increase the degree of protection to IP20 

16

 

Hardware Installation Manual, 02/2021, A5E34871844B 

Fully equipped unit (frame size C with installed mounting kit to increase the degree of 

protection to IP20) 

 

Figure 3-2 

Example of an installed mounting kit to increase the degree of protection to IP20 

Содержание SINAMICS DCM

Страница 1: ......

Страница 2: ......

Страница 3: ...SINAMICS DCM Mounting kit to increase the degree of protection to IP20 Hardware Installation Manual 02 2021 A5E34871844B Preface Ordering data 1 Description 2 Assembling 3 Type test 4 Appendix A ...

Страница 4: ...perated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Si...

Страница 5: ...etail in this Hardware Installation Manual you can request the required information from your local Siemens office We would also like to point out that the contents of this Hardware Installation Manual are neither part of nor modify any prior or existing agreement commitment or contractual relationship The Purchase Agreement contains the complete and exclusive obligations of Siemens including the ...

Страница 6: ...on connecting commissioning maintaining description of functions and service SINAMICS DCM Control Modules Operating Instructions contains all information on ordering installation connecting commissioning maintaining description of functions and service SINAMICS DCM List Manual for DC converters and control modules Contains parameter list function diagrams list of faults and alarms SINAMICS free fu...

Страница 7: ...g kit to increase the degree of protection to IP20 Hardware Installation Manual 02 2021 A5E34871844B 5 Table of contents Preface 3 1 Ordering data 7 2 Description 9 3 Assembling 13 4 Type test 17 A Appendix 19 ...

Страница 8: ...Table of contents Mounting kit to increase the degree of protection to IP20 6 Hardware Installation Manual 02 2021 A5E34871844B ...

Страница 9: ...600 A units 6RX1800 0MA02 Mounting kit to increase the degree of protection to IP20 for 720 A to 850 A units 6RX1800 0MA03 The mounting kits are supplied packed in a cardboard box A product packaging label is attached to the cardboard box Avoid heavy vibration and severe shocks during transportation e g when the cabinet is lowered into position Follow the instructions on the packaging concerning t...

Страница 10: ...Ordering data Mounting kit to increase the degree of protection to IP20 8 Hardware Installation Manual 02 2021 A5E34871844B ...

Страница 11: ...it including all unit covers that are provided installing the mounting kit for degree of protection IP20 and wiring up the unit Cables must be used to establish the power connections for the armature circuit The use of connection busbars is not permitted The radius of the cable lugs for power connections is restricted by the mounting kit For units with rated DC currents from 720 A to 850 A the pro...

Страница 12: ...against direct contact according to IEC 61800 5 1 2007 Technical data The environmental classes and ambient temperatures for the mounting kit correspond to those of the SINAMICS DCM see SINAMICS DCM Operating Instructions Chapter 4 Electronics connections connections onf the CUD The maximum permissible cable diameter is 10 mm further information is provided in the SINAMICS DCM Operating Instructio...

Страница 13: ...ure connection Ø 0 0 mm Ø 16 0 mm Ø 16 0 mm Ø 21 0 mm Protective conductor Ø 0 0 mm Ø 13 0 mm Ø 14 0 mm Ø 17 0 mm Table 2 3 Units with armature current from 400 to 600 A frame size C Connection Cable diameter Set 1 Cable diameter Set 2 1U1 1V1 1W1 line connection Ø 15 0 mm Ø 19 0 mm Ø 19 0 mm Ø 23 0 mm 1C1 1D1 armature connection Ø 18 0 mm Ø 21 0 mm Ø 22 0 mm Ø 26 0 mm Protective conductor Ø 15 0 ...

Страница 14: ...Description Mounting kit to increase the degree of protection to IP20 12 Hardware Installation Manual 02 2021 A5E34871844B ...

Страница 15: ... not be opened until an adequate period of time has elapsed The units listed here contain dangerous rotating machine parts fans and control rotating mechanical parts drives Failure to follow these operating instructions may result in death serious physical injury or extensive material damage Death serious injury or substantial material damage can result if these warning notices are not observed Th...

Страница 16: ...uired 4 Use cable ties to fasten the cables to the cover Pos 3 Attaching the bottom cover cables in front center and rear 1 Attach the cable at the front Pos 9 or Pos 12 for frame size D cover with cable at the center Pos 10 or Pos 13 and cover with cable at the rear Pos 11 or Pos 14 to the side covers Pos 1 and Pos 2 using 4 M4 12 combination screws Pos 109 each Apply the correct tightening torqu...

Страница 17: ...ch the upper cover using cable ties To fully reach degree of protection IP20 the upper cover must only be able to be released using tools For example this can be realized by establishing a snap connection using a 5 mm wide cable tie Figure 3 1 For example this can be realized by establishing a snap connection using a cable tie ...

Страница 18: ...n to IP20 16 Hardware Installation Manual 02 2021 A5E34871844B Fully equipped unit frame size C with installed mounting kit to increase the degree of protection to IP20 Figure 3 2 Example of an installed mounting kit to increase the degree of protection to IP20 ...

Страница 19: ...ion to IP20 Hardware Installation Manual 02 2021 A5E34871844B 17 Type test 4 Final test of the degree of protection After the mounting kit has been installed a type test must be performed to ensure that a degree of protection IP20 has been reached ...

Страница 20: ... Type test Mounting kit to increase the degree of protection to IP20 18 Hardware Installation Manual 02 2021 A5E34871844B ...

Страница 21: ... IP20 Hardware Installation Manual 02 2021 A5E34871844B 19 Appendix A The following 13 pages contain technical drawings including remarks and part numbers to facilitate proper installation For further information please refer to the Chapter Installation ...

Страница 22: ...Mounting Instructions IP20 case size A 15A 30A 1 2 7 197 197 109 109 3Nm 3Nm from inside 3Nm 3Nm 3 109 3Nm 109 3Nm 160 as required cable tie as required sheet 1 of 13 ...

Страница 23: ...6 174 174 see detail A see detail A Pos 174 snap in from the outside detail A 1 1 9 11 109 3Nm 109 3Nm 109 3Nm 109 3Nm sheet 2 of 13 Mounting Instructions IP20 case size A 15A 30A ...

Страница 24: ...1 2 7 197 197 109 109 3Nm 3Nm from inside 3Nm 3Nm 3 109 3Nm 109 3Nm 160 cable tie as required sheet 3 of 13 Mounting Instructions IP20 case size B 60A 280A as required ...

Страница 25: ...6 174 174 see detail A detail A 2 1 sheet 4 of 13 Mounting Instructions IP20 case size B 60A 280A see detail A Pos 174 snap in from the outside ...

Страница 26: ...9 11 109 3Nm 109 3Nm 109 3Nm 109 3Nm 12 14 Pos 12 u 14 for large diameter cable Pos 9 u 11 for small diameter cable sheet 5 of 13 Mounting Instructions IP20 case size B 60A 280A ...

Страница 27: ...1 2 7 197 197 109 109 3Nm 3Nm 3Nm 3 109 3Nm 109 3Nm 160 cable tie as required sheet 6 of 13 Mounting Instructions IP20 case size C 400A 600A from inside 3Nm as required ...

Страница 28: ...6 174 174 see detail A see detail A detail A 2 1 sheet 7 of 13 Mounting Instructions IP20 case size C 400A 600A Pos 174 snap in from the outside ...

Страница 29: ...12 14 9 11 109 3Nm 109 3Nm 109 3Nm 109 3Nm sheet 8 of 13 Mounting Instructions IP20 case size C 400A 600A Pos 12 u 14 for large diameter cable Pos 9 u 11 for small diameter cable ...

Страница 30: ...5 174 on both sides sheet 9 of 13 Mounting Instructions IP20 case size C 400A 600A on both sides ...

Страница 31: ...1 2 7 197 197 109 3Nm 3Nm 3Nm 3 109 3Nm 109 3Nm 160 cable tie as required 8 109 sheet 10 of 13 Mounting Instructions IP20 case size D 720A 850A from inside 3Nm as required ...

Страница 32: ...6 174 174 siehe detail A siehe detail A detail A 2 1 sheet 11 of 13 Mounting Instructions IP20 case size D 720A 850A Pos 174 snap in from the outside ...

Страница 33: ...12 14 9 11 109 3Nm 109 3Nm 109 3Nm 109 3Nm 10 13 Mounting Instructions IP20 case size D 720A 850A Pos 12 13 u 14 for large diameter cable Pos 9 10 u 11 for small diameter cable sheet 12 of 13 ...

Страница 34: ...5 174 sheet 13 of 13 Mounting Instructions IP20 case size D 720A 850A on both sides on both sides ...

Страница 35: ......

Страница 36: ......

Отзывы: