Technical data
10.3 SINAMICS G120D specifications
Converter with the control units CU240D-2
314
Operating Instructions, 04/2018, FW V4.9 SP10, A5E34262100B AF
10.3
SINAMICS G120D specifications
Power Module Specifications
Table 10- 3 Power Module Frame Sizes A and B, 3 AC 380 V … 500 V, ± 10 %
Article No.
6SL3525 -
0PE17-5AA1
0PE21-5AA1
0PE23-0AA1
Output Rating (HO)
[kW]
0.75
1.5
3
Output Power
[kVA]
Rated Input Current
[A]
2.1
3.8
7.2
HO Output Current
[A]
2.2
4.1
7.7
Weight (nett)
[kg]
5.5
5.5
8.5
[lbs]
12.1
12.1
18.7
Weight (packed)
[kg]
6.5
6.5
9.5
[lbs]
14.3
14.3
20.9
Table 10- 4 Power Module Frame Sizes C, 3 AC 380 V … 500 V, ± 10 %
Article No.
6SL3525 -
0PE24-0AA1
0PE25-5AA1
0PE27-5AA1
Output Rating (HO)
[kW]
4
5.5
7.5
Output Power
[kVA]
Rated Input Current
[A]
9.5
12.2
17.7
HO Output Current
[A]
10.2
13.2
19
Weight (nett)
[kg]
9.5
9.5
9.5
[lbs]
20.9
20.9
20.9
Weight (packed)
[kg]
10.5
10.5
10.5
[lbs]
23.1
23.1
23.1
10.4
Data regarding the power loss in partial load operation
You can find data regarding power loss in partial load operation in the Internet: