7.3.4
Editing SINAMICS components
Requirement
● You have loaded all connected DRIVE‑CLiQ components to your user project.
● You have shut down the connection to the target system (offline mode).
Procedure
You can now adapt your components to the application.
Run through the wizard for all the DRIVE‑CLiQ components to be adapted and perform the
required reconfigurations.
This procedure corresponds with the description in Performing the configuration for the D4x5-2
offline (Page 175).
The amount of editing work involved depends on the components used. For example, in the
case of a motor with a DRIVE‑CLiQ interface, the motor and encoder type are identified
automatically.
7.3.5
Downloading a project to the SIMOTION D4x5-2
After you have performed the reconfigurations, you must download the configuration to the
SIMOTION D4x5‑2 (incl. SINAMICS Integrated).
1. Save and compile the project.
2. Go online.
Commissioning (software)
7.3 Performing an online configuration for the D4x5-2
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
209