Note
SIMOTION IT
You can find further information about SIMOTION IT in the following documentation:
● SIMOTION IT Diagnostics and Configuration Diagnostics Manual
● SIMOTION IT Programming and Web Services Programming Manual
● SIMOTION IT Virtual Machine and Servlets Programming Manual
10.8.3.5
Backing up and restoring project data (file structure)
The project data (file structure) is located in the USER directory on the external CFast card
(drive D) of the SIMOTION P320-4.
1. To save the project data, copy the USER directory from the external CFast card, e.g. to a
storage medium of the SIMOTION P320-4 or to a USB flash drive.
2. To restore the project data, copy the USER directory, e.g. from a storage medium of the
SIMOTION P320-4 or a USB flash drive, to the external CFast card and replace the existing
directory.
This also enables series commissioning without a programming device or SIMOTION SCOUT.
65$0
5$0
6WRUDJHPHGLXP
LQWHUQDO
66'
&)DVWFDUG
&)DVWFDUG
6WRUDJHPHGLXP
H[WHUQDO
6,027,21b3
6WRUDJHPHGLD
6,027,21b3
)LUPZDUH
2SHUDWLQJV\VWHP
%DFNXSV
8VHUGDWD
5HWDLQGDWD
.HUQHOGDWD
&XUUHQWGDWD
HJ
86%IODVKGULYH
3*KDUGGLVN
ಹ
([WHUQDOPHPRU\
(QJLQHHULQJ6\VWHP
6,027,213
Figure 10-6 Backing up and restoring a file system
Sequence of a series commissioning
Copy the USER directory from a storage medium to the external CFast card (Drive D) of the
SIMOTION P320-4 to be newly commissioned.
SIMOTION P320-4 must be in the terminated state for this.
Commissioning (software)
10.8 Data storage concept
SIMOTION P320-4 E / P320-4 S
164
Commissioning and Hardware Installation Manual, 11/2016
Содержание SIMOTION P320-4 E
Страница 12: ...Table of contents SIMOTION P320 4 E P320 4 S 12 Commissioning and Hardware Installation Manual 11 2016 ...
Страница 78: ...Use planning SIMOTION P320 4 E P320 4 S 78 Commissioning and Hardware Installation Manual 11 2016 ...
Страница 222: ...Index SIMOTION P320 4 E P320 4 S 222 Commissioning and Hardware Installation Manual 11 2016 ...