Connecting
5.4 System integration
1FK7 G2 synchronous motors
Operating Instructions, 05/2021, A5E50907562B AA
93
5.4.6.3
Motors without a DRIVE-CLiQ interface
If a motor is not equipped with a DRIVE-CLiQ interface, the speed encoder and temperature
sensor are connected via a signal connector.
1
17-pin M23 signal connector
Figure 5-7
Motor with a signal connector
Motors without DRIVE-CLiQ require a Sensor Module Cabinet (SMC) for operation with a
SINAMICS S120 drive system. The motor is connected with the SMC using a MOTION-
CONNECT signal cable.
Figure 5-8
Encoder interface without DRIVE-CLiQ
Information on the connector pin assignment is provided in Chapter "Design of signal