①
CE- or EAC marking
②
Code for prevention of explosions
③
Equipment group: II not for mining, but other hazardous zones
④
Device category: 3 for infrequent, short-term danger
⑤
Atmosphere: G for gas
⑥
Explosion protection: International
⑦
Type of protection: "ec"
⑧
Explosion group: IIB for ethylene
⑨
Temperature Class: T3 for maximum surface temperature 200 °C
⑩
Device protection level: Gc for an extended level of protection in hazardous zones with
explosive gas mixtures
⑪
Identification number or name of nominated testing agency
⑫
Zone 2
⑬
"X" special conditions
Rating plate
The rating plate shows the identification data and the most important technical data. The data
on the rating plate and the contractual agreements define the limits of proper usage.
'
(
:
R
R
R
R
SIEMENS
Figure 3-1
Schematic of the rating plate
Description
SIMOTICS FD 1MM1
24
Operating Instructions 02/2019
Содержание SIMOTICS FD 1MM1 Series
Страница 2: ...05 02 2019 16 03 V11 01 ...
Страница 30: ...Description SIMOTICS FD 1MM1 30 Operating Instructions 02 2019 ...
Страница 50: ...Preparations for use 4 19 Converter operation SIMOTICS FD 1MM1 50 Operating Instructions 02 2019 ...
Страница 94: ...Electrical connection 6 6 Connecting the auxiliary circuits SIMOTICS FD 1MM1 94 Operating Instructions 02 2019 ...
Страница 142: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1MM1 142 Operating Instructions 02 2019 ...
Страница 166: ...Disposal 11 5 Disposal of components SIMOTICS FD 1MM1 166 Operating Instructions 02 2019 ...
Страница 168: ...Service and Support SIMOTICS FD 1MM1 168 Operating Instructions 02 2019 ...
Страница 172: ...Quality documents SIMOTICS FD 1MM1 172 Operating Instructions 02 2019 ...
Страница 177: ......