Parameter description
Note
The SIMOTION identifiers have changed as of V4.0.
You can find a comparison of SIMOTION and SIMATIC names in the Appendix SIMOTION
and SIMATIC names (Page 51).
The busy parameter must not be overwritten by the user. It is supplied and checked by the
function block, and must be supplied with a global variable created by the user only when the
respective function block is called. This parameter coordinates the individual function blocks
for the POSMO A. This ensures that no more than one function block can access a POSMO A
at the same time.
Table 3-1
Parameters of the _POSMOA_control function block
Name
P type
1)
Data type
Default
Meaning
pkwIn
IN
ARRAY [0..7]
of BYTE
8(16#00) Transfer I/O inputs of POSMO A to FB
pzdIn
IN
ARRAY [0..3]
of BYTE
4(16#00) Transfer I/O inputs of POSMO A to FB
enable
IN
BOOL
FALSE
Sets drive to ready for operation
The drive is now ready for operation provided there are no
faults.
homing
IN
BOOL
FALSE
Sets the home position
This signal must be present for at least 50 ms.
releaseBrake
4)
IN
BOOL
FALSE
= TRUE: Release holding brake
= FALSE: Brake sequence control effective
jog1
IN
BOOL
FALSE
Selection of jog 1
If jog 1 and 2 are set simultaneously, a warning is issued and
the drive does not move.
jog2
IN
BOOL
FALSE
Selection of jog 2
If jog 1 and 2 are set simultaneously, a warning is issued and
the drive does not move.
jogOverride
3)
IN
INT
20
Speed override of jogging (0 to 100%)
The override can also be changed during travel.
veloOverride
3)
IN
INT
20
Velocity override (0 to 100%)
This override can also be changed during travel.
start
IN
BOOL
FALSE
= edge FALSE → TRUE: The traversing block specified in
blockNumber is started.
Once a block has been selected in blockNumber, the start
parameter cannot be set until the next block call.
singleBlock
4)
IN
BOOL
FALSE
= TRUE: Automatic single block. Each block has to be re-
started.
= FALSE: AUTOMATIC mode
enableRdIn
4)
IN
BOOL
TRUE
= TRUE: Read-in enable. Next block is enabled for execution.
= FALSE: Read-in disable
Function blocks
3.2 Function block _POSMOA_control
Supplement to SIMODRIVE POSMO A Positioning Motor
20