Bedienhandbuch
SIMATIC HMI SCD1900
Seite 26 / 29
DOC-No.: SCD1900 MANUAL.DOC
4.5
Enclosure
Weight
approx. 5.5 kg
Enclosure material
aluminum
4.6
Mechanical requirements
4.6.1 Operation
Vibration
According to EN 60068-2-6
5 ... 8.5 Hz with ± 3.5 mm deflection
8.5 ... 150 Hz at 1g
Shock
According to EN 60068-2-29
50 m/s², 30 ms
4.6.2 Packed unit
Vibration
According to EN 60068-2-6
5 ... 8.5 Hz with ± 3.5 mm deflection
8.5 ... 500 Hz at 1g
Shock
According to EN 60068-2-29
250 m/s², 6 ms (in storage packaging)
4.7
Input Signal
4.7.1 Digital Signal
Type
Standard signal DVI 1.0
Pixel Frequency
25 – 140 MHz
4.7.2 Analog Signal
Level (Video)
0.7 V
SS
RGB analogue at 75
Ω
Bandwidth
300 MHz (-3dB)
Impedance
75
Ω
Synchronization
- Sep. Sync. (TTL)
- Sync on green
- Composite Sync
H-Frequency
30 to 97 kHz
V-Frequency
50 to 72 Hz