background image

 

SIMATIC RTLS4030T 

 

Device manual, 06/2019, C79000-G8976-C520-02

 

 

 

 

11

 

 

 

 

EN 61000-6-3 
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for 
residential, commercial and light-industrial environments 

 

EN 61000-6-4 
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for 
industrial environments 

Art. 3 (2) Efficient use of the radio spectrum 

 

ETSI EN 300 328 
Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM 
band and using wide band modulation techniques; Harmonised Standard covering the 
essential requirements of article 3.2 of Directive 2014/53/EU 

 

ETSI EN 302 065-2 
Short Range Devices (SRD) using Ultra Wide Band technology (UWB); Harmonised 
Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU;  
Part 2: Requirements for UWB location tracking 

 

 

Note 
The specified approvals apply only when the corresponding mark is printed on the device. 

 

5.4

 

Recycling and disposal

 

The products are low in harmful substances, can be recycled and meet the requirements of the 
Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE). 
Do not dispose of the products at public disposal sites. 
For environmentally compliant recycling and disposal of your electronic waste, please contact a 
company certified for the disposal of electronic waste or your Siemens representative.  
Note the different national regulations. 

 

Mexico: 

La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que 
este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe 
aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada. 

 

Содержание SIMATIC RTLS4030T

Страница 1: ...06 2019 C79000 G8976 C520 02 SIMATIC RTLS Localization systems SIMATIC RTLS4030T Device manual ...

Страница 2: ... accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications describ...

Страница 3: ...ions 5 2 2 Possible states of the LEDs 5 3 Installation initial start up safety 6 3 1 General information 6 3 2 Installation 6 3 3 Battery replacement 6 3 4 Cleaning and maintenance 7 4 Technical data 7 4 1 Radio 7 4 2 Power supply 7 4 3 Environment and dimensions 8 5 Approvals 9 5 1 EU declaration of conformity 9 5 2 RoHS 9 5 3 RED 10 5 3 1 Protection of health and safety 10 5 4 Recycling and dis...

Страница 4: ...the data to the localization server for computation and visualization 1 2 Delivery contents 1 SIMATIC RTLS4030T article number 6GT2700 3DA03 1 VARTA 3 V Lithium CR123A battery 1 3 Power supply The power supply of the device is realized via battery 1 4 Areas of application The device is designed for an operation temperature range from 10 to 50 C The battery of the device needs to be exchanged in dr...

Страница 5: ...SIMATIC RTLS4030T Device manual 06 2019 C79000 G8976 C520 02 5 2 Layout 2 1 Dimensions 2 2 Possible states of the LEDs Status LED display green Description Blinking Power on Flashing Movement starts ...

Страница 6: ...r an optimal location the device has to be mounted such that it has a direct line of sight to the infrastructure devices Before usage of the device check the device for damages such that it will not be damaged during operation The indicated operation temperature ranges must be satisfied The device contains a Lithium battery The improper use of batteries can cause fire and skin burns The case of th...

Страница 7: ...r flammable cleaning aids for cleaning the housing 4 Technical data 4 1 Radio Radio PULSE Location Wireless technology IEEE 802 15 4 2011 UWB Frequency range 3100 MHz 4800 MHz 6000 MHz 7000 MHz Output power 0 037 mW 41 3 dBm MHz Antenna UWB antenna built in Radio PHASE Communication and optional location Wireless technology IEEE 802 15 4 Frequency range 2 40 2 48 GHz ISM Band Output power Max 4 dB...

Страница 8: ...76 C520 02 4 3 Environment and dimensions Environment and dimensions Case Plastic housing IP Protection IP 54 Dimensions approx 89 x 29 x 30 mm Weight approx 90 g incl battery Operation temperature range 10 50 C Type of mounting 2 screws M5 or cable ties ...

Страница 9: ... of the EU L174 01 07 2011 pages 88 110 Radio equipment directive 2014 53 EU RED Radio Equipment Directive Directive of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the Member States relating to the making available on the market of radio equipment official journal of the EU L153 22 05 2014 pages 62 106 5 2 RoHS RoHS directive restriction of the u...

Страница 10: ...1 Common technical requirements ETSI EN 301 489 17 Electromagnetic compatibility and radio spectrum matters ERM Electromagnetic compatibility for radio equipment and services Part 17 Specific conditions for Broadband Data Transmission Systems ETSI EN 301 489 33 Electromagnetic compatibility and radio spectrum matters ERM Electromagnetic compatibility for radio equipment and services Part 33 Specif...

Страница 11: ...quirements of article 3 2 of the Directive 2014 53 EU Part 2 Requirements for UWB location tracking Note The specified approvals apply only when the corresponding mark is printed on the device 5 4 Recycling and disposal The products are low in harmful substances can be recycled and meet the requirements of the Directive 2012 19 EU for disposal of waste electrical and electronic equipment WEEE Do n...

Отзывы: