Accessories
8.1 Wide-range power supply unit for SIMATIC RF systems
RF600
8-6
System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618,
8.1.6
Technical specifications
Table 8-1
General technical specifications
Insulation stability (prim./sec.) U
ins p/s
3.3 kV
AC
Insulation resistance R
ins
>1 GΩ
Leakage current I
leak
U
in
= 230 V
AC
, f = 50 Hz
< 200 µA
Safety class (SELV)
Designed for installation in devices of Safety Class 2
Mains buffering t
h
U
in
= 230 V
AC
≥50 ms
Ambient temperature
-25 °C to +55 °C
Surface temperature
Module top, centrally
max. 96 °C
Storage temperature
-40 °C to +85 °C
Self-heating on full-load
max. 45 K
Interference immunity
ESD
HF fields
Burst
Surge
HF injection
Mains quality test
EN 61000-4-2,
4-3 up to 4-6, 4-11
Air discharge: 15 kV
10 V/m
symmetrical: 2
Symmetrical: 1
10 V
rms
Cooling
Free convection
Dimensions L x W x H
tbd x 85.0 x 35.0 mm
Weight
720 g
Housing / casting
UL 94-V0
Power supply class
according to CSA
Level 3
Table 8-2
Technical specifications for the input
Rated input voltage U
in
EN 60950 / UL 60950
100 to 240 V AC
120 to 353 V
DC
Input voltage range U
in
94 to 264 V AC
120 to 375 V
DC
(UL: 353 V
DC
)
Input frequency f
in
50/60 Hz
Radio interference level
EN 55011/B
Switching frequency f
sw
approx. 70 kHz typ.
Length of cable
2 m
Содержание SIMATIC RF660
Страница 5: ...Table of contents RF600 System Manual 09 2005 Edition J31069 D0171 U001 A0 7618 v ...
Страница 6: ......
Страница 16: ...System overview 3 1 RF System SIMATIC RF600 RF600 3 4 System Manual 09 2005 Edition J31069 D0171 U001 A0 7618 ...
Страница 66: ......
Страница 96: ...Appendix A 4 Training RF600 A 6 System Manual 09 2005 Edition J31069 D0171 U001 A0 7618 ...