Table 8-52
Technical specifications for the MDS D424
6GT2600-4AC00
Product type designation
SIMATIC MDS D424
Memory
Memory configuration
• UID
• 8 bytes
• User memory
• 2000 bytes FRAM
• OTP memory
• 16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Mechanical specifications
Enclosure
• Material
• Epoxy resin
• Color
• Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
ISO transponder
8.18 MDS D424
SIMATIC RF300
System Manual, 02/2021, C79000-G8976-C345-09
369
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...