• Remove residues of adhesive
• Allow to cure according to the manufacturer's instructions
• Flush-mounting of the transponder in metal with tools
Installation examples
0'6
0'6
Figure 8-39
Installation example of MDS D421/D521/E623 in a steep cone
0'6
0'6
Figure 8-40
Installation example of MDS D421/D521/E623 in a stud bolt
8.15.4
Technical specifications
Table 8-44
Technical specifications for the MDS D421
6GT2600-4AE00
Product type designation
SIMATIC MDS D421
Memory
Memory configuration
• UID
• 8 bytes
• User memory
• 2000 bytes FRAM
• OTP memory
• 16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
)
Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 53)"
Mechanical specifications
Enclosure
ISO transponder
8.15 MDS D421
SIMATIC RF300
358
System Manual, 02/2021, C79000-G8976-C345-09
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...