
8.15
MDS D421
8.15.1
Characteristics
MDS D421
Characteristics
Area of application
Constructed for tool coding according to DIN 69873.
It can be used wherever small data storage media and exact
positioning are required,
e.g. tool identification, workpiece holders.
The rugged enclosure of the transponder means that it can
also be used in a harsh industrial environment without prob‐
lems.
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data of ISO transponders (MDS D) (Page 53)"
Mounting on metal
Yes, flush-mounted in metal
ISO standard
ISO 15693
Degree of protection
IP67/IPx9K
8.15.2
Ordering data
Table 8-43
Ordering data of MDS D421
Article number
MDS D421
6GT2600-4AE00
8.15.3
Mounting on metal
Mounting on metal
0HWDO
'DWDPHPRU\
Figure 8-36
Mounting of MDS D421 / D521 on metal
ISO transponder
8.15 MDS D421
SIMATIC RF300
356
System Manual, 02/2021, C79000-G8976-C345-09
Содержание SIMATIC RF300
Страница 14: ...Table of contents SIMATIC RF300 14 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 18: ...Introduction 1 1 Preface SIMATIC RF300 18 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 22: ...Safety information 2 1 Security information SIMATIC RF300 22 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 208: ...Readers 5 6 SIMATIC RF382R with Scanmode 1st generation SIMATIC RF300 208 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 258: ...Antennas 6 10 ANT 30 stainless steel variant SIMATIC RF300 258 System Manual 02 2021 C79000 G8976 C345 09 ...
Страница 474: ...Service Support SIMATIC RF300 474 System Manual 02 2021 C79000 G8976 C345 09 ...