System configuration and system status (web interface)
6.4 Powerline
Power Line Booster
102
Operating Instructions, 11/2019, A5E36203125A-AG
6.4.3
Status tables (master only)
The Power Line Booster system provides the user with a large number of current status
parameters and measured values. The information on the slaves is listed on the following
pages in two tables each. The top table always contains all slaves that are currently
connected to the master. The number of slaves shows in the table is always visible in the
parentheses behind "Connected devices". To show all slaves that have ever been connected
to the master since the last reboot, activate the function "Show devices that are not
connected" below the table. Depending on the number of devices in the system, it may take
a few seconds for these values to load.
If measured values are displayed in the table, these are, by default, short-term measured
values. This means that only the measured values of the last 60 seconds are taken into
account. In addition, the short-term measured values are also reset during each successful
connection to ensure that only the latest data is displayed. If you want to display long-term
measured values, you can do so by pressing the selection button above the table. Long-term
measured values are the measured values since the last restart of the device or since the
last manual reset of the measured values. This measuring duration is always shown above
the table on the respective page. By pressing the "Reset long-term measured values" button,
you reset the long-term measured values of the entire system. However, you only have
access to this function in your capacity as an administrator. Measured values are generally
lost during a restart!
Tables with status parameters only show the current value and thus there is no distinction
between short-term and long-term measured values.
Below the table you can automatically update the values in the table. If the function "Update
automatically" is active, new values are queried cyclically about every 3 seconds. You can
also load new values once by pressing the "Update" button.
All values in the tables can be sorted in ascending or descending order.
If two slaves are mounted on a vehicle (Powerline Double Slider application), this can be
highlighted in color in the table by activating the function "Group stations". The connected
slaves are treated as a unit during sorting.
To get a better overview, most pages let you show or hide columns that are grouped by
topic.
A tooltip provides you with a detailed description of the individual columns when you move
the mouse over the individual column headers.
To interpret the results, we generally recommend to compare the values with each other and
to specifically look at vehicles with potential outliers.