![Siemens SIMATIC NET SCALANCE W721-1 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/siemens/simatic-net-scalance-w721-1/simatic-net-scalance-w721-1_configuration-manual_385652055.webp)
Configuring with Web Based Management
5.3 "Wizard" menu
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
55
The tables of the frequency bands have the following columns:
●
Radio
Shows the available WLAN interfaces in this column.
●
Radio Mode
Shows the mode of the device.
●
Channel number
To specify the valid channels for the required frequency band, select the appropriate
check box for the channel number.
The table displays the permitted channels of the country. Only the valid channels can be
enabled. Invalid channels are grayed out and cannot be enabled.
Note
To specify the channels, the setting "Use Allowed Channels only" must be enabled.
5.3.1.10
Security Settings
Introduction
To make the network secure, authentication and encryption are used. You specify the
security levels with the type of authentication and the encryption procedure.
Note
If "AUTO" or "802.11n" or "802.11n only is set for WLAN Mode "AUTO", only the
authentication types Open System, WPA2 (RADIUS), WPA2-PSK can be set.
Use WPA2/AES, to prevent misuse of a password WPA2 (RADIUS) / WPA2-PSK with AES
provides the greatest security. You will find further information on security in the
configuration manual under "Instructions for secure network design".
The security settings on both devices must match to allow a client to communicate with an
access point.