PROFIBUS connection
2.2 Remote service
Cloud Connector
24
Getting Started, 07/2020, C79000-G8976-C507-03
Steps in configuration
The following steps are required to read out the diagnostic buffer:
1.
Creating a device and user on the SINEMA RC server (Page 24).
2.
Enabling SINEMA RC and TIA Cloud Connector on the device (Page 28).
3.
Connecting the VPN tunnel to the SINEMA RC server with the SINEMA RC client (Page 30).
4.
Enabling the TIA Cloud Connector on the server (Page 31).
5.
Connecting via the TIA Portal Cloud Connector (Page 33).
2.2.2
Creating a device and user on the SINEMA RC server
Requirement
•
The SINEMA RC is accessible and you are logged on to the WBM with administrator rights.
Create participant group
1.
In the navigation area, click "Remote connections" > "Participant groups".
2.
Click the "Create" button and create a group named "Service_Admin".
3.
Enable "Members may communicate with each other".
4.
Enable "LAN1" at "Network interfaces accessible through the VPN tunnel".
5.
Click the "Save" button.
Creating a device
1.
In the navigation area, click on "Remote connections" > "Device".
2.
Click the "Create" button and configure the "Device settings":
Facility
Parameter
Setting
Device information
Device name
M804PB
New password
Enter a password and repeat it.
Password Confirmation
Vendor
Siemens
Type
SCALANCE S615 / M804PB / M826 /
M816
VPN settings
-
Apply default settings
All access
Participant group
Select the "Service_Admin" group and
click the "Add" button.
Содержание SIMATIC NET SCALANCE M80PB
Страница 6: ...Preface Cloud Connector 6 Getting Started 07 2020 C79000 G8976 C507 03 ...
Страница 8: ...Table of contents Cloud Connector 8 Getting Started 07 2020 C79000 G8976 C507 03 ...
Страница 10: ...Description Cloud Connector 10 Getting Started 07 2020 C79000 G8976 C507 03 ...
Страница 27: ...PROFIBUS connection 2 2 Remote service Cloud Connector Getting Started 07 2020 C79000 G8976 C507 03 27 ...
Страница 37: ...PROFIBUS connection 2 2 Remote service Cloud Connector Getting Started 07 2020 C79000 G8976 C507 03 37 ...
Страница 38: ......
Страница 60: ...PROFINET connection 3 2 Remote service Cloud Connector 60 Getting Started 07 2020 C79000 G8976 C507 03 ...
Страница 62: ...Index Cloud Connector 62 Getting Started 07 2020 C79000 G8976 C507 03 ...