background image

Technical Specifications
5.5 Dimension Drawings

31

.8

463.8

4.7

6.

35

29

.0

51

.1

16

1.

0

21

2.

1

11.7

21.1

Figure 5.2

Rack Mount Dimensions

 

 

 

 

 

479.0

16

0.

0

13

4.

6

68

.8

489.2

51

.6

11.7

29

.0

51

.1

16

1.

0

21

2.

1

21.1

Figure 5.3

Panel and Din Rail Mount Dimensions

46

RUGGEDCOM RX1536

Installation Manual, 04/2021, C79000-G8976-1488-02

Содержание SIMATIC NET RUGGEDCOM RX1500

Страница 1: ...Edition 04 2021 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1536 https www siemens com ...

Страница 2: ...ugged Multi Service Platforms RUGGEDCOM RX1536 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Modules 4 Technical Specifications 5 Certification 6 04 2021 C79000 G8976 1488 02 ...

Страница 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 4: ...evice 5 2 1 General Procedure 6 2 2 Unpacking the Device 6 2 3 Mounting the Device 7 2 3 1 Mounting the Device to a Rack 7 2 3 2 Mounting the Device on a DIN Rail 8 2 3 3 Mounting the Device to a Panel 9 2 4 Connecting the Failsafe Alarm Relay 10 2 5 Connecting Power 11 2 5 1 Connecting High AC DC Power 12 2 5 2 Connecting Low DC Power 15 3 Device Management 21 3 1 Connecting to the Device 21 3 2 ...

Страница 5: ... Mechanical Specifications 44 5 5 Dimension Drawings 44 6 Certification 49 6 1 Approvals 49 6 1 1 UL 49 6 1 2 TÜV SÜD 49 6 1 3 European Union EU 50 6 1 4 FCC 51 6 1 5 FDA CDRH 51 6 1 6 ISED 51 6 1 7 ISO 52 6 1 8 RoHS 52 6 1 9 Other Approvals 52 6 2 EMC and Environmental Type Tests 52 iv RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 6: ...es https support industry siemens com cs ww en view 109747072 RUGGEDCOM SFP Transceivers Catalog https support industry siemens com cs ww en view 109482309 Accessing Documentation The latest user documentation for RUGGEDCOM RX1536 is available online at https support industry siemens com To request or inquire about a user document contact Siemens Customer Support Registered Trademarks RUGGEDCOM RO...

Страница 7: ...s customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure us...

Страница 8: ...ncluding FAQs and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 10: ...ts Immunity to EMI and high voltage electrical transients 40 to 85 C 40 to 185 F operating temperature no fans Failsafe output relay for critical failure or error alarming Universal Power Supply Options Input voltage ranges 13 36 VDC and 37 72 VDC or 85 264 VAC and 88 300 VDC for worldwide operability CSA UL 62368 1 safety approved to 85 C 185 F Physical Ports Field replaceable line modules Up to ...

Страница 11: ...RX1536 software or install files such as configuration files and feature key files For more information refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1536 Lamp Test Alarm Cut Off LT ACO Button This button performs two functions Press and hold this button to test all indicator LEDs Press and release this button to acknowledge an active alarm Power Status LEDs Indicates the sta...

Страница 12: ... Decommissioning This device may include sensitive proprietary data Before taking the device out of service either permanently or for maintenance by a third party make sure it has been fully decommissioned For more information refer to the associated Configuration Manual Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a faci...

Страница 13: ...tions required for proper Gigabit Ethernet operation For reliable error free data communication new and pre existing communication paths should be verified for TIA EIA 568 A compliance The following table summarizes the relevant cabling standards Cabling Category 1000Base TX Compliant Required Action 5 No New wiring infrastructure required 5 Yes Verify TIA EIA 568 A compliance 5e Yes No action req...

Страница 14: ... 47 CFR section 1 1307 addressing Radio Frequency RF exposure from radio frequency base stations as defined in FCC OET Bulletin 65 http transition fcc gov Bureaus Engineering_Technology Documents bulletins oet65 oet65 pdf The emitted radiation should be as little as possible To achieve minimum RF exposure install the device when it is configured not to transmit and set it to operational mode remot...

Страница 15: ...nment of the device including maintaining the integrity of all protective conductor connections and checking equipment ratings Make sure to review all operating and installation instructions before commissioning or performing maintenance on the device 1 Review the relevant certification information for any regulatory requirements For more information refer to Approvals Page 49 2 Review the RUGGEDC...

Страница 16: ...h either rack DIN rail or panel hardware installed refer to Dimension Drawings Page 44 2 3 1 Mounting the Device to a Rack For rack mount installations the RUGGEDCOM RX1536 can be equipped with rack mount adapters pre installed at the front or rear of the chassis Additional adapters are provided for added stability NOTICE Vibration hazard risk of damage to the device Always use four rack mount ada...

Страница 17: ...tall the rack mount adapters at the rear of the chassis To make the management ports and LEDs accessible install the rack mount adapters at the front of the chassis Note The chassis features multiple mounting holes allowing the rack mount adapters to be installed up to 25 mm 1 in from the face of the device 3 3 1 2 1 Rear 2 Front 3 Rack Mount Adapter Figure 2 1 Rack Mount Adapters 2 If required in...

Страница 18: ...igure 2 2 DIN Rail Mounting 2 Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails 2 3 3 Mounting the Device to a Panel For panel installations the RUGGEDCOM RX1536 can be equipped with panel DIN rail adapters pre installed on each side of the chassis The adapters allow the device to be attached to a panel using screws RUGGEDCOM RX1536 Installatio...

Страница 19: ...based on alarm conditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RX1536 One common application for this relay is to signal an alar...

Страница 20: ...l injury or death Make sure all power sources are off before servicing the power module terminals NOTICE Use minimum 16 gage copper wiring when connecting terminal blocks The maximum wire length between the terminal block and power source must not exceed 6 m 20 ft for 24 V power supplies or 18 m 60 ft for 48 V power supplies For 125 230 VAC rated equipment an appropriately rated AC circuit breaker...

Страница 21: ...k of death serious personal injury and or damage to the device Make sure the supplied cover is always installed over high voltage screw terminal blocks NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 12 24 or 48 VDC power supply terminal block Damage to the power supply may occur 12 RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 22: ... L Terminal 3 Ground Terminal 4 Negative Neutral N Terminal Figure 2 5 AC Terminal Block Wiring European style Euroblock Terminal Block for HIP Power Supplies 4 5 6 4 1 5 1 6 2 3 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Live L Terminal 5 Ground Terminal RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 13 ...

Страница 23: ...ect the positive wire from the power source to the positive live L terminal on the terminal block 3 Connect the negative wire from the power source to the neutral negative N terminal on the terminal block 4 For screw terminal blocks install the safety cover 4 3 2 1 1 Screw 2 Safety Cover 3 Screw Terminal Block 4 RUGGEDCOM RX1536 Device Figure 2 7 Assembling the Safety Cover 5 Using a braided wire ...

Страница 24: ...ction Figure 2 8 Ground Connection 7 Install the safety cover over the terminal block 2 5 2 Connecting Low DC Power To connect a low DC power supply to the device do the following NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 12 24 or 48 VDC power supply terminal block Damage to the power supply may occur Note The RUGGEDCOM RX1536 works with both positive...

Страница 25: ...erminal 3 Negative Terminal 4 Ground Terminal Figure 2 9 DC Terminal Block Wiring European style Euroblock Terminal Block for 12P 24P and 48P Power Supplies 4 5 6 5 1 6 1 4 2 3 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Terminal 5 Negative Terminal 16 RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 26: ...Terminal Block 2 Positive Terminal 3 Negative Terminal 4 Ground Terminal Figure 2 11 DC Terminal Block Wiring European style Euroblock Terminal Block for 12P 24P and 48P Power Supplies 3 4 5 6 2 5 1 4 1 6 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Terminal 5 Negative Terminal RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 17 ...

Страница 27: ...n Make sure no bare metal is exposed beyond the safety cover 2 Connect the positive wire from the power source to the positive terminal on the terminal block 3 Connect the negative wire from the power source to the negative terminal on the terminal block 4 For screw terminal blocks install the safety cover 4 3 2 1 1 Screw 2 Safety Cover 3 Screw Terminal Block 4 RUGGEDCOM RX1536 Device Figure 2 13 ...

Страница 28: ...n the device Make sure the lug is tightened to 2 4 N m 21 lbf in 3 2 1 4 1 10 Ring Lug 2 10 32 Screw 3 Connection from External Power Source 4 Ground Connection Figure 2 14 Ground Connection 6 Install the safety cover over the terminal block This is mandatory for 48 VDC and 48 VDC power supplies RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 19 ...

Страница 29: ...Installing the Device 2 5 2 Connecting Low DC Power 20 RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 30: ...J45 connectors the slots on the connector where the contacts connect is too short causing the connector pins in the port to lift before a proper connection is made It is determined the minimum slot length must be 5 5 mm 0 216 in 5 5 mm Adjusting the position of the connector in the port either by wiggling or pulling the connector back corrects the issue temporarily but is not recommended It may ca...

Страница 31: ... refer to the RUGGEDCOM ROX CLI Configuration Manual for the RUGGEDCOM RX1536 For information about how to connect to the device via the management port refer to either the RUGGEDCOM ROX Web Interface Configuration Manual or the RUGGEDCOM ROX CLI Configuration Manual for the RUGGEDCOM RX1536 The management port is a 10 100Base TX copper Ethernet port with an RJ 45 connector The following is the pi...

Страница 32: ...e the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM RX1536 interface For more information about configuring the device refer to the RUGGEDCOM ROX Configuration Manual associated with the installed software release RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 23 ...

Страница 33: ...Device Management 3 2 Configuring the Device 24 RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 34: ...OM RX1536 is also available Use the RUGGEDCOM ROX software to determine which ports are equipped on the device For more information refer to the RUGGEDCOM ROX Configuration Manual for the device 4 1 Requirements and Restrictions Before installing modules in the device consider the following restrictions and requirements Module Support Slots 1 and 2 are reserved for 2 port copper and fiber Ethernet...

Страница 35: ... WAN Cell 3G LTE 7 W 2 Port Copper M12 RJ45 4 W 4 Port Copper M12 RJ45 5 W 6 Port Copper M12 RJ45 5 W WAN T1 E1 3 W Serial S01 3 W Example A device with the following modules installed would exceed the power budget for line modules 41 5 W Module Quantity Consumption RUGGEDCOM APE1808 2 24 W 2 Port Fiber Optic FG50 SFPs 2 14 W 6 Port Copper M12 RJ45 1 5 W Total Consumption 43 W 4 2 Available Module...

Страница 36: ... Euroblock Article Numbers 6GK6015 0AL18 0AA0 Standard 6GK6015 0AL18 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS 24 shipped until 2019 Specifications Input Range 13 to 36 VDC Terminal Type Non removable Screw Article Numbers 6GK6015 0AL11 0AA0 Standard 6GK6015 0AL11 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS 24 shipped from 2019 on Specifications Input Range 13 to 36 VDC Terminal Type Removable S...

Страница 37: ...o 72 VDC Terminal Type European style Euroblock Article Numbers 6GK6015 0AL15 0AA0 Standard 6GK6015 0AL15 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS HI shipped until 2019 Specifications Input Range 88 to 300 VDC or 85 to 264 VAC Terminal Type Non removable Screw Article Numbers 6GK6015 0AL13 0AA0 Standard 6GK6015 0AL13 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS HI shipped from 2019 on Specificat...

Страница 38: ...rt Type M12 8 Pin A Coded Distance 100 m 328 ft Power Consumption 4 W Article Numbers 6GK6015 0AL20 0PB0 Standard 6GK6015 0AL20 0PB1 Conformal Coated RUGGEDCOM RX1500PN LM CG03B Specifications Ports 2 Speed 1000 Mbps Interface TX Port Type M12 8 Pin A Coded Controlled Bypass Distance 100 m 328 ft Power Consumption 4 W Article Numbers 6GK6015 0AL20 0PE0 Standard 6GK6015 0AL20 0PE1 Conformal Coated ...

Страница 39: ...ecifications Ports 4 Speed 100 Mbps Interface TX Port Type M12 8 Pin A Coded Controlled Bypass Distance 100 m 328 ft Power Consumption 5 W Article Numbers 6GK6015 0AL20 0PF0 Standard 6GK6015 0AL20 0PF1 Conformal Coated RUGGEDCOM RX1500PN LM 4TX04 Specifications Ports 4 Speed 100 Mbps Interface TX Port Type M12 4 Pin D Coded Distance 100 m 328 ft Power Consumption 5 W Article Numbers 6GK6015 0AL20 ...

Страница 40: ...6GK6015 0AL20 0BC0 Standard 6GK6015 0AL20 0BC1 Conformal Coated RUGGEDCOM RX1500PN LM FL01 Specifications Mode MM Speed 10 100 Mbps Interface FL SX Wavelength 820 nm Ports 3 Port Type ST Distance 2 km 1 2 mi Power Consumption 5 W Article Numbers 6GK6015 0AL20 0BD0 Standard 6GK6015 0AL20 0BD1 Conformal Coated RUGGEDCOM RX1500PN LM FG03 Specifications Mode SM Speed 1000 Mbps Interface LX Wavelength ...

Страница 41: ... 0AL20 0JC1 Conformal Coated RUGGEDCOM RX1500PN LM FX51 Specifications Mode SM Speed 100 Mbps Interface FX Wavelength 1310 nm Ports 2 Port Type LC Distance 2 km 1 2 mi Power Consumption 5 W Article Numbers 6GK6015 0AL20 0BJ0 Standard 6GK6015 0AL20 0BJ1 Conformal Coated RUGGEDCOM RX1500PN LM 6FX50 Specifications SFP Sockets 6 Speed 100 Mbps Power Consumption 7 W Article Numbers 6GK6015 0AL20 0JD0 S...

Страница 42: ...umption 7 W Article Numbers 6GK6015 0AL20 0WB0 Standard 6GK6015 0AL20 0WB1 Conformal Coated RUGGEDCOM RX1500PN LM W41 Specifications Services 4G LTE HSPA HSDPA HSUPA DC HSPA UMTS WCDAM EDGE GPRS GSM GNSS Region European Union Port Type 50 Ω SMA Antennas 1 x LTE Main 1 x LTE MIMO 1 x GPS SIM Dual Mini SIM 2FF Power Consumption 7 W Article Numbers 6GK6015 0AL20 0WG0 Standard 6GK6015 0AL20 0WG1 Confo...

Страница 43: ... Conformal Coated RUGGEDCOM RX1500PN LM W81 Specifications Services 4G LTE HSPA EDGE GPRS GSM UMTS GNSS Region Asia Pacific Port Type 50 Ω SMA Antennas 1 x LTE Main 1 x LTE MIMO 1 x GPS SIM Dual Mini SIM 2FF Power Consumption 7 W Article Numbers 6GK60150AL200WK0 Standard 6GK60150AL200WK1 Conformal Coated RUGGEDCOM APE Modules RUGGEDCOM RX1500PN LM APE1402 Obsolete Specifications Operating System D...

Страница 44: ...DVI D Power Consumption 10 W Article Numbers 6GK6015 0AL20 0GC0 Standard 6GK6015 0AL20 0GC1 Conformal Coated RUGGEDCOM RX1500PN LM APE1404 Obsolete Specifications Operating System Debian Linux Processor Intel Atom E660T 1 3 GHz 512 KB L2 Cache RAM 2 GB DDR2 800 MHz 32 bit Disk 16 GB SATA Solid State Networking Realtek RTL8111 RJ45 Gigabit Ethernet Interface USB 2 x USB 2 0 a Video Intel 4108 Graph...

Страница 45: ...or Intel Atom E660T 1 3 GHz 512 KB L2 Cache RAM 2 GB DDR2 800 MHz 32 bit Disk 16 GB SATA Solid State Networking Realtek RTL8111 RJ45 Gigabit Ethernet Interface USB 2 x USB 2 0 a Video Intel 4108 Graphics Processor DVI D Power Consumption 10 W Article Numbers 6GK6015 0AL20 0GE0 Standard 6GK6015 0AL20 0GE1 Conformal Coated RUGGEDCOM RX1500PN LM APE1404CKP Obsolete Specifications Operating System Che...

Страница 46: ...dard 6GK6015 0AL20 0GH1 Conformal Coated RUGGEDCOM RX1536PN LM APE1808W10 Specifications Operating System Windows 10 Enterprise 2019 LTSC Processor Intel x5 E3940 1 8 GHz 2 MB L2 Cache RAM 8 GB DDR3 ECC 1600 MHz 64 bit Disk 64 GB Solid State Networking Intel I210 RJ45 Gigabit Ethernet Interface USB 2 x USB 3 0 Video Intel HD Graphics Processor Display Port Power Consumption 12 W Article Numbers 6G...

Страница 47: ...te Networking Intel I210 RJ45 Gigabit Ethernet Interface USB 2 x USB 3 0 Video Intel HD Graphics Processor Display Port Power Consumption 12 W Article Numbers 6GK6015 0AL20 0GK0 Standard 6GK6015 0AL20 0GK1 Conformal Coated a Maximum combined USB device power consumption is 500 mA at 5 V Blank Modules RUGGEDCOM RX1500PN PS XXP Specifications Article Numbers 6GK6015 0AL10 0AA0 Standard 6GK6015 0AL10...

Страница 48: ...W i e the total power made available to the modules by the chassis If the total power consumption exceeds this value power fluctuations and irregular shut downs may occur For the maximum power consumption of each line module refer to Available Modules Page 26 NOTICE Contamination hazard risk of equipment damage Prevent the ingress of water dirts and other debris that may lead to premature equipmen...

Страница 49: ...all the device in the rack Installing a Module To install a line module do the following 1 Optional If the device is installed in a rack remove it from the rack 2 Remove the current module from the slot 3 Insert the new module into the slot 1 2 3 1 Module 2 Chassis 3 Screw Figure 4 3 Installing a Module 4 Tighten the screws to secure the module 5 Optional If necessary install the device in the rac...

Страница 50: ...Removing a Power Module To remove a power module do the following DANGER Electrocution hazard risk of serious personal injury or death Make sure power to the module is turned off before servicing the power supply terminal 1 Turn off power to the module 2 Loosen the screws that secure the module to the chassis until the module can be removed 3 2 1 Figure 4 5 Removing a Power Supply 3 Slide the modu...

Страница 51: ...supplied terminal block to the module or connect the terminal block from the previous module 3 Confirm or connect the wiring from the power supply to the module For more information refer to Connecting Power Page 11 4 Insert the module into the empty slot 3 2 1 Figure 4 6 Installing a Power Module 5 Hand tighten the screws to secure the power module to the chassis 6 Turn on power to the device and...

Страница 52: ...300 VDC HIP 85 VAC 264 VAC 3 15 A T b 65 W 2800 VDC for 1 minute 24 24P 13 VDC 36 VDC 10 A T b 63 5 W 48 48P 36 VDC 72 VDC 3 15 A T b 60 W 1500 VDC for 1 minute 12 12P 9 VDC 15 VDC 12 A 67 W 1500 VAC or 2121 VDC for 1 minute a Power consumption varies based on the device configuration b T denotes time delay fuse 5 2 Failsafe Relay Specifications Maximum Switching Voltage Rated Switching Current Is...

Страница 53: ...ng Temperature ab 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity c 5 to 95 Maximum Altitude 12192 m 40000 ft a Measured from a 30 cm 12 in radius surrounding the center of the enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non con...

Страница 54: ...Technical Specifications 5 5 Dimension Drawings 44 2 440 9 296 7 Figure 5 1 Overall Dimensions RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 45 ...

Страница 55: ... 8 4 7 6 35 29 0 51 1 161 0 212 1 11 7 21 1 Figure 5 2 Rack Mount Dimensions 479 0 160 0 134 6 68 8 489 2 51 6 11 7 29 0 51 1 161 0 212 1 21 1 Figure 5 3 Panel and Din Rail Mount Dimensions 46 RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 56: ...ons 5 5 Dimension Drawings 19 7 151 4 102 9 113 3 162 5 Figure 5 4 Line Module Dimensions 162 5 40 6 151 8 102 9 113 4 Figure 5 5 Power Module Dimensions RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 47 ...

Страница 57: ...Technical Specifications 5 5 Dimension Drawings 48 RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 58: ...he requirements of the following standards CAN CSA C22 2 NO 62368 1 07 R2014 Information Technology Equipment Safety Part 1 General Requirements Bi National standard with UL 62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements Certification is filed under E361664 6 1 2 TÜV SÜD This device is certified by TÜV SÜD to meet the requirements of the following standards ...

Страница 59: ...ance Directive 2014 53 EU Directive 2014 53 EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999 5 EC Text with EEA relevance EN 62368 1 Information Technology Equipment Safety Part 1 General Requirements EN 61000 3 2 Electromagnetic comp...

Страница 60: ...radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense Note Changes or modifications not expressly approved by the party responsi...

Страница 61: ...the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 6 1 9 Other Approvals This device meets the requirements of the following additional standards IEEE 1613 IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations IEC 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic St...

Страница 62: ...us 1000 A m for 1 s Note a IEC 61000 4 8 Magnetic Field Enclosure Ports 1000 A m for 1 s 5 IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 30 for 1 period 60 for 50 periods Signal ports DC Power Ports IEC 61000 4 12 Damped Oscillatory AC Power Ports 2 5 kV common 1 kV differential mode 1 MHz 3 Signal ports IEC 61000 4 16 Mains Frequency Voltage DC Power Ports 30 V Continuous 300 V for 1 ...

Страница 63: ...Oscillatory AC Power Ports 2 5 kV common 1 kV differential mode 1 MHz Radiated RFI Enclosure ports 35 V m Enclosure Contact 8 kV ESD Enclosure Air 15 kV Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 5...

Страница 64: ...est Description Test Levels Severity Levels IEC 60529 Ingress Protection IP4x Military Standard Tests Test Description Test Levels MIL STD 810G Altitude 12192 m 40000 ft 40 C 90 minutes RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 55 ...

Страница 65: ...Certification 6 2 EMC and Environmental Type Tests 56 RUGGEDCOM RX1536 Installation Manual 04 2021 C79000 G8976 1488 02 ...

Страница 66: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: