Installation Manual

SIMATIC NET

Rugged Ethernet Switches

RUGGEDCOM RSL910

https://www.siemens.com/ruggedcom

Содержание SIMATIC NET RUGGEDCOM RSL910

Страница 1: ...Edition 04 2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSL910 https www siemens com ruggedcom ...

Страница 2: ...ed Ethernet Switches RUGGEDCOM RSL910 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 04 2022 C79000 G8976 1305 13 ...

Страница 3: ...those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used the...

Страница 4: ...l Procedure 8 2 2 Unpacking the Device 8 2 3 Mounting the Device 8 2 3 1 Mounting the Device on a DIN Rail 9 2 3 2 Mounting the Device to a Panel 11 2 4 Connecting the Failsafe Alarm Relay 13 2 5 Connecting Power 13 2 5 1 Connecting High AC DC Power 14 2 5 2 Connecting Low DC Power 16 3 Device Management 19 3 1 Connecting to the Device 19 3 2 Configuring the Device 21 4 Communication Ports 23 4 1 ...

Страница 5: ...cations 32 5 5 Operating Environment 33 5 6 Mechanical Specifications 33 5 7 Dimension Drawings 33 6 Certification 37 6 1 Approvals 37 6 1 1 CSA 37 6 1 2 European Union EU 37 6 1 3 FCC 38 6 1 4 FDA CDRH 38 6 1 5 ISED 38 6 1 6 TÜV SÜD 39 6 1 7 ISO 39 6 1 8 RoHS 39 6 1 9 Other Approvals 39 6 2 EMC and Environmental Type Tests 40 iv RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 ...

Страница 6: ...support industry siemens com cs ww en view 109482309 SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document The glossary is available online via Siemens Industry Online Support SIOS at https support industry siemens com cs ww en view 50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RSL910 is available online at https supp...

Страница 7: ...s customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure us...

Страница 8: ...s and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 ...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 ...

Страница 10: ...DCOM RSL910 to be placed in almost any location The RUGGEDCOM RSL910 provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found on plant floors and curb side traffic control cabinets An operating temperature range of 40 to 85 C 40 to 185 F coupled optional conformal coating and a galvanized steel enclosure allows the RUGGEDCOM RSL910...

Страница 11: ...Galvanized Steel DIN or panel mounting options provide secure mechanical reliability Optional Conformal coated printed circuit boards Power Supply Fully integrated power supply Universal high voltage range 125 250 VDC or 100 240 VAC Hazardous Environments 88 300 VDC or 85 264 VAC Non Hazardous Environments Dual LO DC inputs 24 or 48 VDC Terminal blocks for reliable maintenance free connections CSA...

Страница 12: ...tions For information about connecting to the device via the serial console port refer to Connecting to the Device Page 19 Communication Ports Communication ports in general receive and transmit data as well as provide access to the RUGGEDCOM ROS Web interface For more information about the various ports available refer to Communication Ports Page 23 Failsafe Alarm Relay Latches to default state w...

Страница 13: ...r maintenance by a third party make sure it has been fully decommissioned For more information refer to the associated Configuration Manual Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a facility certified to dispose of waste electrical and electronic equipment Recycling and disposal must be done in accordance with local ...

Страница 14: ...ditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 5 ...

Страница 15: ...Introduction 1 5 1 Supported Fiber Optic Cables 6 RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 ...

Страница 16: ...iation exposure CAUTION Burn hazard risk of personal injury The surface of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with or around the device NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and vo...

Страница 17: ...e failsafe alarm relay 4 Connect power to the device and ground the device to safety Earth 5 Connect the device to the network 6 Configure the device 2 2 Unpacking the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included Note If any item is missing or ...

Страница 18: ...the rack space Note For detailed dimensions of the device with either DIN rail or panel hardware installed refer to Dimension Drawings Page 33 2 3 1 Mounting the Device on a DIN Rail The RUGGEDCOM RSL910 can be ordered with a DIN rail adapter preinstalled on the back of the chassis Use the adapter to mount the device to a standard 35 mm 1 4 in IEC EN 60715 or TS35 DIN rail RUGGEDCOM RSL910 Install...

Страница 19: ...liding release with a slot at the bottom for a flathead screwdriver 1 2 3 2 1 1 1 DIN Rail 2 DIN Rail Adapter Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a flathead screwdriver into the slot of the sliding release and move it down 3 Push the device against the bottom of the DIN rail then let go of the sliding release to latch the device 10 RUGGEDCOM RSL910 Installation Manual 04 2022 C79...

Страница 20: ...IN Rail Adapter Figure 2 2 Removing the Device from a DIN Rail 2 Swing the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 2 3 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RSL910 can be equipped with panel adapters on the top and bottom of the chassis The adapters allow the device to be attached to a panel using screws RUGGEDCOM RSL910 Insta...

Страница 21: ...mbly 2 Slide the supplied adapters under the screw heads and then tighten the screws 3 Prepare mounting holes in the panel where the device is to be installed 4 Place the device against the panel and align the adapters with the mounting holes 2 1 1 2 1 Screw M3 5 or 6 32 2 Panel Mount Adapter Figure 2 4 Panel Mounting 5 Secure the adapters to the panel with M3 5 or 6 32 screws 12 RUGGEDCOM RSL910 ...

Страница 22: ...ation refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RSL910 To connect the failsafe alarm relay do the following 1 Insert the failsafe alarm relay terminal block into the device and tighten the screws 2 Connect a failsafe device to the terminal block 1 2 3 1 Normally Closed 2 Common 3 Normally Open Figure 2 5 Failsafe Alarm Relay Wiring 2 5 Connecting Power The RUGGEDCOM RSL910 ...

Страница 23: ...age 50 V to 200 V Insertion Loss 0 1 dB at 10 MHz Peak Surge Current 10 kA 8x20 µs waveform 2 5 1 Connecting High AC DC Power To connect a high AC DC power supply to the device do the following NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to terminals for DC power Damage to the power supply may occur NOTICE Electrical hazard risk of damage to equipment Before...

Страница 24: ... power source to the positive live L terminal on the terminal block 4 1 2 3 1 Positive Live L Terminal 2 Negative Neutral N Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 6 Terminal Block Wiring 1 3 1 2 2 4 RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 15 ...

Страница 25: ... power source to the chassis groun terminal on the terminal block 2 5 2 Connecting Low DC Power RUGGEDCOM RSL910 s equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply To connect a low DC power supply to the device do the following Note Torque all terminal connec...

Страница 26: ...minal block 1 3 1 2 2 4 1 Positive Terminal 2 Negative Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 8 Terminal Block Wiring Single DC Power Supply Inputs 3 Connect the negative wire from the power source to the negative terminal on the terminal block RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 17 ...

Страница 27: ... Terminal Block Wiring Dual DC Power Supply Inputs 5 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 6 Connect the ground wire from the power source to the chassis groun terminal on the terminal ...

Страница 28: ...e B console port to access the boot time control and RUGGEDCOM RSL910 interfaces The console port provides access to RUGGEDCOM RSL910 s console interface Note Console ports are intended to be used only as a temporary connection during initial configuration or troubleshooting Note When the USB Type B console port is in use the serial console port will echo the console output but not accept any user...

Страница 29: ...s RS232 DCE Data Communication Equipment on a DB9 connector The following is the pin out for the port 1 5 9 6 Figure 3 2 Serial DB9 Console Port Pin Name Description 1 a Reserved Do Not Connect 2 TX Transmit Data 3 RX Receive Data 4 a Reserved Do Not Connect 5 GND Signal Ground 6 a Reserved Do Not Connect 7 b Reserved Do Not Connect 8 b Reserved Do Not Connect 9 Reserved Do Not Connect a Connected...

Страница 30: ...ttps 192 168 0 1 For more information about available ports refer to Communication Ports Page 23 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM RSL910 interface For more information about configuring the device refer to the RUGGEDCOM ROS Configuration Manual associated with the instal...

Страница 31: ...Device Management 3 2 Configuring the Device 22 RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 ...

Страница 32: ...ent Port Type 1 to 6 Copper Ethernet Ports 10 100Base TX 7 and 8 SFP Transceivers 1000Base TX BX FX SX LX 9 and 10 Universal EoVDSL Ports 4 1 Copper Ethernet Ports The RUGGEDCOM RSL910 supports multiple 10 100Base TX Ethernet ports that allow connection to standard Category 5 CAT 5 shielded or unshielded twisted pair cables with RJ45 male connectors RUGGEDCOM RSL910 Installation Manual 04 2022 C79...

Страница 33: ...res a Speed and Link Activity LED that indicates the state of the port 1 2 1 Speed LED 2 Link Activity LED Figure 4 2 RJ45 Port LEDs LED State Description Yellow The port is operating at 100 Mbps Speed Off The port is operating at 10 Mbps Yellow Solid Link established Yellow Blinking Link activity Link Activity Off No link detected Pin Out The following is the pin out for the RJ45 male connectors ...

Страница 34: ...e used interchangeably for the Slave All EoVDSL line configuration settings are modified on the Master and pushed to the Slave Data flowing from the Master to the Slave is designated downstream while data flowing from the Slave to the Master is designated upstream IMPORTANT Universal EoVDSL ports master or slave must be connected to other Universal EoVDSL ports slave or master Connections between ...

Страница 35: ...ive interference as they reduce the magnetic loop area to nearly zero and maintain a consistent distribution of capacitances to both ground and other sources Therefore make sure twisting is consistent throughout the cable length Open leads also known as bridged taps or drop lines along the length of the cable will cause an impedance mismatch and result in VDSL signal degradation Make sure the cabl...

Страница 36: ... 85 Mbps etc or to determine the optimal bit rate automatically based on the current line conditions When a specific bit rate is selected the device will only attempt to attain the selected speed Signal Degradation An EoVDSL terminal in Master mode can be configured to automatically scan the available VDSL profiles for a more optimal link The terminal can be configured to initiate the scan when th...

Страница 37: ...8 0 9 m 3 ft 85 85 23 6 0 9 m 3 ft 55 55 29 8 0 9 m 3 ft 35 35 34 6 0 9 m 3 ft 25 25 37 3 0 9 m 3 ft 11 11 38 3 0 9 m 3 ft 4 7 4 7 41 7 0 9 m 3 ft 2 4 2 4 42 8 0 9 m 3 ft 1 2 1 2 43 4 0 9 m 3 ft 0 5 0 5 43 8 0 9 m 3 ft 0 2 0 2 44 4 3 SFP Transceivers The RUGGEDCOM RSL910 supports up to two Small Form Factor Pluggable SFP transceiver sockets which are compatible with a wide array of SFP transceiver...

Страница 38: ...ing and installation removal refer to the RUGGEDCOM SFP Transceiver Catalog https support industry siemens com cs ca en view 109482309 Note Only use SFP transceivers approved by Siemens for RUGGEDCOM products Siemens accepts no liability as a result of performance issues related in whole or in part to third party components RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 29 ...

Страница 39: ...Communication Ports 4 3 SFP Transceivers 30 RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 ...

Страница 40: ...00 VAC 240 VAC 3 15 A T 4 kVAC 10 W 24 12 VDC 24 VDC 3 15 A T 1 5 kVDC 10 W 48 37 VDC 72 VDC 3 15 A T 1 5 kVDC 10 W a T denotes time delay fuse b Power consumption varies based on configuration Non Hazardous Environments Input Voltage Power Supply Type Minimum Maximum Internal Fuse Rating a Isolation Maximum Power Consumption b 88 VDC 300 VDC 3 15 A T 4 kVAC 12 W HI 85 VAC 264 VAC 3 15 A T 5 5 kVD...

Страница 41: ...s for 1 minute 5 3 Supported Networking Standards The following networking standards are supported by RUGGEDCOM RSL910 Standard 10 Mbps Ports 100 Mbps Ports 1000 Mbps Ports Notes IEEE 802 3x Full Duplex Operation IEEE 802 3z 1000Base LX IEEE 802 3ab 1000Base Tx IEEE 802 1D MAC Bridges IEEE 802 1Q VLAN Virtual LAN IEEE 802 1p Priority Levels 5 4 Copper Ethernet Port Specifications The following det...

Страница 42: ...to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity c 5 to 95 Maximum Altitude 2000 m 6562 ft a Measured from a 30 cm 12 in radius surrounding the center of the enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non condensing 5 6 Mechanical ...

Страница 43: ...Technical Specifications 5 7 Dimension Drawings 124 7 116 6 65 1 168 7 180 5 Figure 5 1 Overall Dimensions 34 RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 ...

Страница 44: ...ical Specifications 5 7 Dimension Drawings 120 6 101 6 ø 8 1 198 9 99 1 57 2 186 2 78 8 13 7 ø 4 0 ø 4 0 Figure 5 2 Panel Mount Dimensions RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 35 ...

Страница 45: ...Technical Specifications 5 7 Dimension Drawings 126 2 89 6 134 3 Figure 5 3 DIN Rail Mount Dimensions 36 RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 ...

Страница 46: ... 1 Information Technology Equipment Safety Part 1 General Requirements 6 1 2 European Union EU This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives EN 62368 1 Information Technology Equipment Safety Part 1 General Requirements EN 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic Standards Immunit...

Страница 47: ... energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense Note Changes or modifications not expressly approved by the party responsible for complia...

Страница 48: ...Ltd to meet the requirements of the following RoHS Restriction of Hazardous Substances directives for the restricted use of certain hazardous substances in electrical and electronic equipment China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en ...

Страница 49: ... 3 Radiated RFI Enclosure Ports 10 and 20 V m 3 Signal Ports 2 kV 4 DC Power Ports 2 kV 3 AC Power Ports 2 kV 3 IEC 61000 4 4 Burst Fast Transient Earth Ground Ports 1 kV 2 Signal Ports 2 kV 2 DC Power Ports 2 kV Line to Ground 1 kV Line to Line 1 IEC 61000 4 5 Surge AC Power Ports 2 kV Line to Ground 1 kV Line to Line 2 Signal Ports 10 V 3 DC Power Ports 10 V 3 AC Power Ports 10 V 3 IEC 61000 4 6...

Страница 50: ...ld Temperature Test Ae 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Be 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 Non Condensing 55 C 131 F 6 Cycles IEC 60255 21 1 Vibration 2 g 10 to 150 Hz Class 2 IEC 60255 21 2 Shock 30 g 11 ms Class 2 RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 41 ...

Страница 51: ...Certification 6 2 EMC and Environmental Type Tests 42 RUGGEDCOM RSL910 Installation Manual 04 2022 C79000 G8976 1305 13 ...

Страница 52: ...dustry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario L4K 4E5 Canada 2022 Siemens Canada Ltd Subject to change ...