4.4.2 Removing a GBIC Optical Port

5. Squeeze the latches on either side of the port and insert the port into the socket.

2

1

3

     1    

GBIC Optical Port Module

     2    

Socket

     3    

Locking Latch

Figure 4.8

Installing a GBIC Optical Port

6. Release the latches and make sure the port is locked in place.

NOTICE

Only remove the dust plug when ready to connect a cable to the GBIC optical

port.

7. Remove the dust cover from the port and store for future use.
8. Remove the dust cap from the cable and immediately connect it to the port.
9. Connect the cable to a network and observe the LED associated with the port.

For more information about the LED, refer to 

"

Communication Ports

 (Page

23)"

.

4.4.2

Removing a GBIC Optical Port

To remove an GBIC optical port, do the following:

NOTICE

Electrical hazard – risk of damage to equipment

Make sure all electrostatic energy is dissipated before performing installing or

removing components from the device. An electrostatic discharge (ESD) can cause

serious damage to the component once it is outside the chassis.

1. Make sure all potential electrostatic build-up has been properly discharged to

prevent an electrostatic discharge (ESD). This can be accomplished by wearing

an ESD-preventive wrist trap connected to either the chassis ground connector

or a bare metal surface on the router/switch.

28

RUGGEDCOM RSG2200F

Installation Manual, 04/2022, C79000-G8976-1346-10

Содержание SIMATIC NET RUGGEDCOM RSG2200F

Страница 1: ...Edition 04 2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG2200F https www siemens com ruggedcom ...

Страница 2: ...d Ethernet Switches RUGGEDCOM RSG2200F Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 04 2022 C79000 G8976 1346 10 ...

Страница 3: ...those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used the...

Страница 4: ...Supported Fiber Optic Cables 5 1 6 Tamper Evident Security Seals 5 2 Installing the Device 7 2 1 General Procedure 8 2 2 Unpacking the Device 8 2 3 Mounting the Device 8 2 3 1 Mounting the Device to a Rack 9 2 3 2 Mounting the Device on a DIN Rail 10 2 3 3 Mounting the Device to a Panel 11 2 4 Connecting the Failsafe Alarm Relay 12 2 5 Connecting Power 13 2 5 1 Connecting AC or DC Power 14 2 5 2 W...

Страница 5: ...ng Standards 31 5 4 Copper Ethernet Port Specifications 32 5 5 Fiber Optic Ethernet Port Specifications 33 5 6 Operating Environment 34 5 7 Mechanical Specifications 34 5 8 Dimension Drawings 35 6 Certification 39 6 1 Approvals 39 6 1 1 CSA 39 6 1 2 European Union EU 39 6 1 3 FCC 40 6 1 4 FDA CDRH 40 6 1 5 ISED 41 6 1 6 ISO 41 6 1 7 RoHS 41 6 1 8 Other Approvals 41 6 2 EMC and Environmental Type T...

Страница 6: ...pport industry siemens com cs ca en view 109482309 SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document The glossary is available online via Siemens Industry Online Support SIOS at https support industry siemens com cs ww en view 50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RSG2200F is available online at https supp...

Страница 7: ... customer service representative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site customized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the essential practical skills to make sure use...

Страница 8: ... and manuals Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 2...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 ...

Страница 10: ...C LC SC without loss of port density The RUGGEDCOM RSG2200F is packaged in a rugged galvanized steel enclosure with industrial grade DIN panel or 48 cm 19 in rack mount mounting options 1 1 Feature Highlights Ethernet Ports Up to 9 x Gigabit Ethernet ports copper and fiber Up to 9 x 100Base FX Fiber Fast Ethernet ports 2 port modules for tremendous flexibility Non blocking store and forward switch...

Страница 11: ...unting configuration 3 4 2 1 5 7 6 1 Fiber or Copper Ethernet Ports 2 Port Status Indicator LEDs 3 Mode Button 4 RS 232 Serial Console Port RJ45 5 Display Mode Indicator LEDs 6 Alarm Indicator LED 7 Power Module Indicator LEDs Figure 1 1 RUGGEDCOM RSG2200F Communication Ports Ports for communicating with other devices or accessing the RUGGEDCOM RSG2200F operating system are described in Communicat...

Страница 12: ...l management functions For information about connecting to the device via the serial console port refer to Connecting to the Device Page 21 1 3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG2200F Tools Materials Purpose AC power cord 16 AWG For connecting power to the device CAT 5 Ethernet cables For connecting the device to the network Fla...

Страница 13: ...ound potential rise i e greater than 2500 V during line to ground fault conditions 1 5 2 Gigabit Ethernet 1000Base TX Cabling Recommendations The IEEE 802 3ab Gigabit Ethernet standard defines 1000 Mbit s Ethernet communications over distances of up to 100 m 328 ft using all 4 pairs in category 5 or higher balanced unshielded twisted pair cabling For wiring guidelines system designers and integrat...

Страница 14: ...odal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized 1 6 Tamper Evident Security Seals In compliance with the security requirements of the Federal Information Processing Standards FIPS140 2 FIPS compliant tamp...

Страница 15: ... device under ultra violet light For information about the placement of security seals refer to the RUGGEDCOM RSG2200F FIPS 140 2 Non Proprietary Security Policy https support industry siemens com cs ww en view 109757984 6 RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 ...

Страница 16: ...ures other than those specified herein may result in hazardous radiation exposure NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications test results and agency approvals and void the user s authority to operate ...

Страница 17: ...en unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included Note If any item is missing or damaged contact Siemens for assistance 2 3 Mounting the Device The RUGGEDCOM RSG2200F is designed for maximum mounting and display flexibility It can be equipped with connectors...

Страница 18: ...erating ambient temperature of the rack may be higher than the ambient temperature of the room Make sure the rack is installed in a suitable environment that can withstand the maximum ambient temperature generated by the rack Make sure each device in the rack is separated by at least one rack unit of space or 44 mm 1 75 in to promote convectional airflow Forced airflow is not required However any ...

Страница 19: ...t of the chassis Note The chassis features multiple mounting holes allowing the rack mount adapters to be installed up to 25 mm 1 in from the face of the device 1 2 3 3 1 Rear 2 Front 3 Rack Mount Adapter Figure 2 1 Rack Mount Adapters 2 If required install adapters on the opposite side of the device to protect from vibrations 3 Insert the device into the rack 4 Secure the adapters to the rack usi...

Страница 20: ...ure 2 2 DIN Rail Mounting 2 Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails 2 3 3 Mounting the Device to a Panel For panel installations the RUGGEDCOM RSG2200F can be equipped with panelDIN rail adapters pre installed on each side of the chassis The adapters allow the device to be attached to a panel using screws RUGGEDCOM RSG2200F Installati...

Страница 21: ...onditions The NO Normally Open contact is closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RSG2200F One common application for this relay is to signal an alarm if a power f...

Страница 22: ...onnections under severe shock or vibration NOTICE Electrical hazard risk of damage to the device Make sure power input to the device is within the specified input range For information about the nominal input range for the device refer to Power Supply Specifications Page 31 Note For maximum redundancy in a dual power supply configuration use two independent power sources Use minimum 16 gage copper...

Страница 23: ...sis ground and must be removed in order to avoid damage to transient suppression circuitry during testing NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 24 or 48 VDC power supply Damage to the power supply may occur IMPORTANT Each internal power module is labeled POWER 1 or POWER 2 Make sure to connect the power supply to the corresponding internal power m...

Страница 24: ...Terminal 7 Chassis Ground Terminal 8 Chassis Ground Connection Figure 2 5 Terminal Block Wiring 5 Connect the negative wire from the power source to the negative neutral N terminal on the terminal block 6 Install the supplied metal jumper between terminals 2 4 and 6 to connect the surge ground terminals to the chassis ground terminal The surge ground terminals are used as the ground conductor for ...

Страница 25: ...2 6 32 Screw 3 6 Ring Lug Figure 2 6 Chassis Ground Connection DANGER Electrocution hazard risk of death serious personal injury and or damage to the device Make sure the supplied terminal block cover is always installed before the device is powered 8 Install the terminal block cover 2 5 2 Wiring Examples The following illustrate how to connect power to single and dual power supplies 16 RUGGEDCOM ...

Страница 26: ...Installing the Device 2 5 2 Wiring Examples Figure 2 7 Single AC Power Supply Figure 2 8 Single DC Power Supply RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 17 ...

Страница 27: ...Installing the Device 2 5 2 Wiring Examples Figure 2 9 Dual AC Power Supply Figure 2 10 Dual DC Power Supply 18 RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 ...

Страница 28: ...Installing the Device 2 5 2 Wiring Examples Figure 2 11 Dual AC DC Power Supply RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 19 ...

Страница 29: ...Installing the Device 2 5 2 Wiring Examples 20 RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 ...

Страница 30: ...s to RUGGEDCOM RSG2200F s console and Web interfaces NOTICE The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting Connection to the console port is made using an RJ45 to DB9 console cable The following is the pin out for the console port 1 8 Figure 3 1 RJ45 Console Port Pin Configuration Pin RJ45 Male DB9 Female Name Descripti...

Страница 31: ...nd access the RUGGEDCOM RSG2200F console and Web interfaces via the device s IP address For more information about available ports refer to Communication Ports Page 23 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM RSG2200F interface For more information about configuring the device r...

Страница 32: ...GGEDCOM RSG2200F chassis Slot 5 supports a one port fiber or copper Ethernet module up to 1 Gbps All other ports support any combination of fiber or copper Ethernet connectors up to 1 Gbps The exact configuration of the device can be determined by reading the factory data file through the RUGGEDCOM RSG2200F user interface For more information about how to read the factory data file refer to the RU...

Страница 33: ...hassis ground on the device and can accept CAT 5 shielded twisted pair STP cables WARNING Electric shock hazard risk of serious personal injury and or equipment interference If shielded cables are used make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end Ground loops can cause excessive noise and interference but more importantly create...

Страница 34: ...al Pair D 8 Reserved Do Not Connect BI_DD Receive Data or Bi Directional Pair D Specifications For specifications on the available copper Ethernet ports refer to Copper Ethernet Port Specifications Page 32 4 2 Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either LC Lucent Connector SC Standard or Subscriber Connector or ST Straight Tip connectors Make sure the Transmit T...

Страница 35: ...link detected Compatible SFP Transceivers For more information about which SFP transceivers are compatible with the RUGGEDCOM RSG2200F as well as instructions for ordering and installation removal refer to the RUGGEDCOM SFP Transceiver Catalog https support industry siemens com cs ca en view 109482309 IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products Siemens accepts no...

Страница 36: ...us damage to the component once it is outside the chassis NOTICE Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2200F 1 Make sure all potential electrostatic build up has been properly discharged to prevent electrostatic discharges ESD This can be accomplished by wearing an ESD preventive wrist strap connected to either the chassis ground connector or a bare metal surfac...

Страница 37: ...d with the port For more information about the LED refer to Communication Ports Page 23 4 4 2 Removing a GBIC Optical Port To remove an GBIC optical port do the following NOTICE Electrical hazard risk of damage to equipment Make sure all electrostatic energy is dissipated before performing installing or removing components from the device An electrostatic discharge ESD can cause serious damage to ...

Страница 38: ...cket 2 1 3 1 Socket 2 GBIC Optical Port 3 Locking Latch Figure 4 9 Removing a GBIC Optical Port 4 Store the port in an ESD safe bag or other suitable ESD safe environment free from moisture and stored at the proper temperature 40 to 85 C or 40 to 185 F 5 Insert a dust plug into the socket opening to prevent the ingress of dust and dirt RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 13...

Страница 39: ...Communication Ports 4 4 2 Removing a GBIC Optical Port 30 RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 ...

Страница 40: ...5 250 VDC d 88 VDC 300 VDC 2 A T HI 110 230 VAC d 85 VAC 264 VAC 2 A T 28 W a F denotes fast acting fuse b T denotes time delay fuse c Power consumption varies based on configuration 10 100Base TX ports consume roughly 1 W less than fiber optic ports d The HI power supply is the same power supply for both AC and DC 5 2 Failsafe Relay Specifications Maximum Switching Voltage 250 VAC 125 VDC Rated S...

Страница 41: ...fications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RSG2200F Note Maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associate when determining maximum segment distances All optical power numbers are listed as dBm averages F51 transceivers are rate...

Страница 42: ... 125 1310 5 0 35 3 50 30 SM SC 9 125 1310 0 5 37 0 90 37 SM LC 9 125 1310 0 5 37 0 90 37 a Typical b Typical distance The maximum distance is greatly dependent on factors such as cable type the number of connectors and number of splices Consult a Siemens sales associates when determining maximum distances Gigabit Ethernet 1 Gbps Optical Specifications Note These transceivers utilize a distributed ...

Страница 43: ...herwise b Typical c All optical power numbers are listed as dBm averages d Typical distance The maximum segment length is greatly dependent on factors such as fiber quality and the number of patches and splices Consult a Siemens sales associates when determining maximum segment distances e Operating temperature range of 25 to 85 C 13 to 185 F 5 6 Operating Environment The RUGGEDCOM RSG2200F is rat...

Страница 44: ... All dimensions are in millimeters unless otherwise stated Note Dimensional tolerances are in accordance with ISO 2768 mK unless otherwise stated 285 49 438 15 313 18 44 45 0 8 Figure 5 1 Overall Dimensions RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 35 ...

Страница 45: ...ns 5 8 Dimension Drawings 479 29 28 96 51 05 25 40 11 68 32 77 461 0 6 35 31 75 9 9 6 35 470 4 21 08 12 70 313 18 308 35 Figure 5 2 Rack Mount Dimensions 36 RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 ...

Страница 46: ...s 5 8 Dimension Drawings 134 3 51 6 159 8 84 1 285 5 486 4 476 3 38 9 125 5 80 0 11 7 158 0 127 5 7 4 10 4 Figure 5 3 Panel and DIN Rail Mount Dimensions RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 37 ...

Страница 47: ...Technical Specifications 5 8 Dimension Drawings 38 RUGGEDCOM RSG2200F Installation Manual 04 2022 C79000 G8976 1346 10 ...

Страница 48: ...rd with UL 62368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements The Certificate Body CB test certificate is available on SIOS at https support industry siemens com cs ww en view 109794212 6 1 2 European Union EU This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives EN 62368 ...

Страница 49: ...onable protection against harmful interference when the equipment is operated in a commercial environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which ca...

Страница 50: ...tricted use of certain hazardous substances in electrical and electronic equipment China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 6 1 8 Other Approvals This device meets the requirements of the following additional standards...

Страница 51: ...ion Test Levels Severity Levels Enclosure Contact 8 kV IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure Ports 20 V m Note a Signal Ports 4 kV 2 5 kHz Note a DC Power Ports AC Power Ports IEC 61000 4 4 Burst Fast Transient Earth Ground Ports 4 kV 4 Signal Ports 4 kV Line to Ground 2 kV Line to Line 4 DC Power Ports 2 kV Line to Ground 1 kV Line to Line 3 IEC 61000 4 5 Su...

Страница 52: ... Ports 5 kV Fail Safe Relay Output DC Power Ports IEC 60255 5 HV Impulse AC Power Ports 5 kV a Siemens specified severity levels EMC Immunity Type Tests per IEEE 1613 Note RUGGEDCOM products meet Class 1 requirements for copper Ethernet configurations and Class 2 for fiber Ethernet configurations Class 1 allows for temporary communication loss while Class 2 requires error free and interrupted comm...

Страница 53: ...kV Dielectric Strength AC Power Ports 2 kV Damped Oscillatory Magnetic Field Enclosure Ports 100 A m Environmental Type Tests Test Description Test Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 Non Condensing 55 C 131 F 6 Cycles IEC 60068 21 1 Vibration 2g 10 150 Hz IEC 60068 2...

Страница 54: ...dustry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens Canada Ltd Digital Industries Process Automation 300 Applewood Crescent Concord Ontario L4K 4E5 Canada 2022 Siemens Canada Ltd Subject to change ...