background image

Edition

04/2021

Installation Manual

SIMATIC NET

Rugged Ethernet Switches

RUGGEDCOM RS910W

https://www.siemens.com

Содержание SIMATIC NET RUGGEDCOM RS910W

Страница 1: ...Edition 04 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS910W https www siemens com ...

Страница 2: ...ed Ethernet Switches RUGGEDCOM RS910W Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 04 2021 C79000 G8976 1031 12 ...

Страница 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 4: ...2 3 Installing the Device in Hazardous Locations 8 2 4 Mounting the Device 9 2 4 1 Mounting the Device on a DIN Rail 10 2 4 2 Mounting the Device to a Panel 11 2 5 Connecting the Antennas 12 2 6 Connecting the Failsafe Alarm Relay 13 2 7 Connecting Power 14 2 7 1 Connecting High AC DC Power 15 2 7 2 Connecting Low DC Power 17 3 Device Management 21 3 1 Connecting to the Device 21 3 2 Configuring t...

Страница 5: ...2 Failsafe Alarm Relay Specifications 32 5 3 Supported Networking Standards 32 5 4 Copper Ethernet Port Specifications 32 5 5 Fiber Optic Ethernet Port Specifications 33 5 6 Serial Port Specifications 33 5 7 Operating Environment 34 5 8 Mechanical Specifications 34 5 9 Dimension Drawings 34 6 Certification 37 6 1 Approvals 37 6 1 1 CSA 37 6 1 2 FCC 38 6 1 3 FDA CDRH 38 6 1 4 ISED 38 6 1 5 ISO 38 6...

Страница 6: ...rt Registered Trademarks RUGGEDCOM ROS RCDP and RUGGEDCOM Discovery Protocol are registered trademarks of Siemens Canada Ltd Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Warranty Siemens warrants this product for a period of five 5 years from the date of purchase conditional upon the return to factory...

Страница 7: ...cture technologies Siemens unique mix of IT Telecommunications expertise combined with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com or contact a Siemens Sales representative Customer Support Customer supp...

Страница 8: ...emens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 vii ...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 ...

Страница 10: ...twork security features including strong encryption protocols using WPA with TKIP and even WPA2 802 11i with 128 bit AES encryption Static authentication support is provided by WPA PSK For additional centralized control the RUGGEDCOM RS910W also supports IEEE 802 1X RADIUS for wireless user traffic and distributing dynamic encryption keys The RUGGEDCOM RS910W provides a high level of immunity to e...

Страница 11: ...ctrical surges Hazardous Location Certification Class I Division 2 40 to 85 C 40 to 185 F ambient operating temperature no fans 20 AWG Galvanized Steel DIN or panel mounting options provide secure mechanical reliability Optional Conformal coated printed circuit boards Power Supply Fully integrated power supply Universal high voltage range 125 250 VDC or 100 240 VAC Hazardous Environments 88 300 VD...

Страница 12: ...bout connecting to the device via the serial console port refer to Connecting to the Device Page 21 Communication Ports Communication ports in general receive and transmit data as well as provide access to the RUGGEDCOM ROS Web interface For more information about the various ports available refer to Communication Ports Page 23 Failsafe Alarm Relay Latches to default state when a power disruption ...

Страница 13: ...ance by a third party make sure it has been fully decommissioned For more information refer to the associated Configuration Manual Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a facility certified to dispose of waste electrical and electronic equipment Recycling and disposal must be done in accordance with local regulatio...

Страница 14: ...ditions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 5 ...

Страница 15: ...Introduction 1 5 1 Supported Fiber Optic Cables 6 RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 ...

Страница 16: ... radiation exposure CAUTION Burn hazard risk of personal injury The surface of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with or around the device NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null an...

Страница 17: ...als Page 37 2 Mount the device 3 Install and connect the antennas 4 Connect the failsafe alarm relay 5 Connect power to the device and ground the device to safety Earth 6 Connect the device to the network 7 Configure the device 2 2 Unpacking the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any p...

Страница 18: ... be appropriately connected to safety Earth upon installation Note For further details of the device s compliance with Class I Division 2 standards refer to Approvals Page 37 NOTICE Do not disconnect or open equipment unless power has been switched off or the area is known to be non hazardous NOTICE Substitution of the components may impair suitability for Class I Division 2 2 4 Mounting the Devic...

Страница 19: ...ter to mount the device to a standard 35 mm 1 4 in IEC EN 60715 or TS35 DIN rail Mounting the Device To mount the device to a DIN rail do the following 1 Hook the top teeth of the adapter onto the DIN rail Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver 1 2 3 2 1 1 1 DIN Rail 2 DIN Rail Adapter Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a...

Страница 20: ...r Figure 2 2 Removing the Device from a DIN Rail 2 Swing the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 2 4 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RS910W can be equipped with panel adapters pre installed on the top and bottom of the chassis The adapters allow the device to be attached to a panel using screws To mount the device to...

Страница 21: ...as The RUGGEDCOM RS910W supports two dipole antennas that can be rotated 360 around the connection point and up to 90 at the joint for optimal positioning Note The RUGGEDCOM RS910W is shipped with two 2 4 GHz dipole antennas Note For technical specifications refer to Wireless Ethernet Ports Page 26 To connect the antennas do the following 1 Make sure the operating frequency range of each antenna i...

Страница 22: ...s closed when the unit is powered and there are no active alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RS910W One common application for this relay is to signal an alarm if a power failure occurs For more information refer t...

Страница 23: ... For 125 250 VDC rated equipment an appropriately rated DC circuit breaker must be installed Use minimum 16 gage copper wiring when connecting terminal blocks Equipment must be installed according to applicable local wiring codes and standards All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remove the gr...

Страница 24: ...l hazard risk of damage to equipment Before testing the dielectric strength HIPOT in the field remove the braided ground cable connected to the surge ground terminal and chassis ground This cable connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing Note Torque all terminal connections to 0 6 N m 5 ...

Страница 25: ...om the power source to the positive live L terminal on the terminal block 4 1 2 3 1 Positive Live L Terminal 2 Negative Neutral N Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 6 Terminal Block Wiring 16 RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 ...

Страница 26: ...om the power source to the chassis groun terminal on the terminal block 2 7 2 Connecting Low DC Power RUGGEDCOM RS910W s equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply To connect a low DC power supply to the device do the following Note Torque all terminal ...

Страница 27: ...erminal block 1 3 2 4 1 Positive Terminal 2 Negative Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 8 Terminal Block Wiring Single DC Power Supply Inputs 3 Connect the negative wire from the power source to the negative terminal on the terminal block 18 RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 ...

Страница 28: ... Terminal Block Wiring Dual DC Power Supply Inputs 5 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 6 Connect the ground wire from the power source to the chassis groun terminal on the terminal ...

Страница 29: ...Installing the Device 2 7 2 Connecting Low DC Power 20 RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 ...

Страница 30: ...not energized Console Port Connect a workstation directly to the RS232 serial console port to access the boot time control and RUGGEDCOM ROS console interface The console port provides access to RUGGEDCOM RS910W s console interface Note The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting and should only be used in a safe are...

Страница 31: ...Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS910W console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RS910W is https 192 168 0 1 For more information about available ports refer to Communication Ports Page 23 3 2 Configuring the Device Once the device is installed and connected...

Страница 32: ...gnment Port Type 1 and 2 Serial Ports 3 and 4 Copper 10 100Base TX or Fiber Optic 100Base FX Ethernet Ports 9 Wireless Antennas 4 1 Copper Ethernet Ports The RUGGEDCOM RS910W supports multiple 10 100Base TX Ethernet ports that allow connection to standard Category 5 CAT 5 shielded or unshielded twisted pair cables with RJ45 male connectors RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 ...

Страница 33: ...res a Speed and Link Activity LED that indicates the state of the port 1 2 1 Speed LED 2 Link Activity LED Figure 4 2 RJ45 Port LEDs LED State Description Yellow The port is operating at 100 Mbps Speed Off The port is operating at 10 Mbps Yellow Solid Link established Yellow Blinking Link activity Link Activity Off No link detected Pin Out The following is the pin out for the RJ45 male connectors ...

Страница 34: ...ubscriber Connector or ST Straight Tip connectors Make sure the Transmit Tx and Receive Rx connections of each port are properly connected and matched to establish a proper link Port Types 2 1 1 Tx Connector 2 Rx Connector Figure 4 4 MTRJ Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 5 LC Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 6 SC Port 2 1 1 Tx Connector 2 Rx Connector Figure 4 7 ST Po...

Страница 35: ... Mbps WLAN Full Access Point 2 4 GHz ISM IEEE 802 11b 11 Mbps WLAN Client support Backwards compatibility Strong Encryption WPA2 AES CCMP Robust Secure Network RSN Enhanced Encryption WPA TKIP RC4 Temporal keys IEEE 802 11i Basic Encryption WEP RC4 Up to 4 static keys IEEE 802 1x Wireless Authentication Personal or Enterprise PSK or RADIUS 4 3 2 Radio Characteristics Modulation Direct Sequence Spr...

Страница 36: ... channels 9 through 11 can be used indoors and outdoors Users are responsible for making sure the channel set configuration complies with the regulatory standards of Mexico Regulatory Domains Channel Identifier Frequency MHz America A EMEA E Japan J Rest of World W 1 2412 2 2417 3 2422 4 2427 5 2432 6 2437 7 2442 8 2447 9 2452 10 2457 11 2462 12 2467 13 2472 14 a 2484 a Not supported in Japan for ...

Страница 37: ...cription for the RS232 RS485 RS422 DB9 ports 1 5 9 6 Figure 4 8 RS232 RS485 RS422 DB9 Serial Console Port Name Pin a RS232 Mode RS485 Mode RS422 Mode 1 b DCD 2 TX TX RX TX 3 RX RX 4 b DTR 5 Common Isolated Ground c 6 b DSR RX 7 d CTS e TX RX TX 8 d RTS e 9 RI No Connection Shield Chassis Ground a No internal termination is provided b Connected internally c The Common terminal is isolated However t...

Страница 38: ... A DTE that asserts RTS will see CTS asserted although the device will not perform hardware flow control 4 4 3 Serial RS232 RS485 RS422 Fiber Ports The RS910W can be equipped with serial RS232 RS485 RS422 fiber ports Each port can be set individually through the RUGGEDCOM RS910W operating system to operate in RS232 RS485 or RS422 mode For more information refer to the RUGGEDCOM ROS Configuration M...

Страница 39: ...219 m 4000 ft at 100 kbps The Common terminals should be connected to the common wire inside the shield The shield should be connected to earth ground at a single point to avoid loop currents The twisted pair should be terminated at each end of the chain The following shows the recommended RS485 wiring 1219 m 4000 in 120Ω 10nF 120Ω 10nF 1 2 3 5 5 6 4 1 RUGGEDCOM RS910W Device 2 Common Isolated Gro...

Страница 40: ...00 VAC 240 VAC 3 15 A T 4 kVAC 10 W 24 12 VDC 24 VDC 3 15 A T 1 5 kVDC 10 W 48 37 VDC 72 VDC 3 15 A T 1 5 kVDC 10 W a T denotes time delay fuse b Power consumption varies based on configuration Non Hazardous Environments Input Voltage Power Supply Type Minimum Maximum Internal Fuse Rating a Isolation Maximum Power Consumption b 88 VDC 300 VDC 3 15 A T 4 kVAC 10 W HI 85 VAC 264 VAC 3 15 A T 5 5 kVD...

Страница 41: ...s for 1 minute 5 3 Supported Networking Standards The following networking standards are supported by RUGGEDCOM RS910W Standard 10 Mbps Ports 100 Mbps Ports 1000 Mbps Ports Notes IEEE 802 3x Full Duplex Operation IEEE 802 3z 1000Base LX IEEE 802 3ab 1000Base Tx IEEE 802 1D MAC Bridges IEEE 802 1Q VLAN Virtual LAN IEEE 802 1p Priority Levels 5 4 Copper Ethernet Port Specifications The following det...

Страница 42: ...d the number of patches and splices Consult a Siemens sales associate when determining maximum segment distances Tx dBm Mode Connector Type Tx λ nm a Cable Type μm Minimum Maximum Rx Sensitivity dBm Rx Saturation dBm Distance km a Power Budget dB 62 5 125 1300 19 14 31 14 2 12 MM ST 50 125 1300 22 5 14 31 14 2 8 5 62 5 125 1300 19 14 31 14 2 12 MM SC 50 125 1300 22 5 14 31 14 2 8 5 MM MTRJ 62 5 12...

Страница 43: ...ronmental conditions Ambient Operating Temperature a 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity b 5 to 95 Maximum Altitude 2000 m 6562 ft a Measured from a 30 cm 12 in radius surrounding the center of the enclosure b Non condensing 5 8 Mechanical Specifications Weight 1 2 kg 2 7 lbs Ingress Protection IP30 Enclosure 20 AWG Galvanized Steel 5...

Страница 44: ...Technical Specifications 5 9 Dimension Drawings 99 06 187 96 168 66 65 3 116 59 7 87 Figure 5 1 Overall Dimensions RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 35 ...

Страница 45: ... Specifications 5 9 Dimension Drawings 13 64 101 6 11 2 78 74 120 65 194 06 83 20 183 90 132 9 Figure 5 2 Panel and DIN Rail Mount Dimensions 36 RUGGEDCOM RS910W Installation Manual 04 2021 C79000 G8976 1031 12 ...

Страница 46: ...afety Part 1 General Requirements CAN CSA C22 2 No 0 M91 General Requirements Canadian Electrical Code Part II CAN CSA C22 2 No 142 M1987 Process Control Equipment Industrial Products CAN CSA C22 2 No 213 16 Non Incendive Electrical Equipment for Use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Bi National Standard with ANSI ISA 12 12 01 2016 UL 916 S...

Страница 47: ...r complies with Part 15 sub part C of the FCC rules and is approved under the ID VG5RW80G Note Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this device 6 1 3 FDA CDRH This device meets the requirements of the following U S Food and Drug Administration FDA standard Title 21 Code of Federal Regulations CFR Chapter ...

Страница 48: ...rdous substances in electrical and electronic equipment China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 6 1 8 Other Approvals This device meets the requirements of the following additional standards IEEE 1613 IEEE Standard En...

Страница 49: ...round 2 kV 4 DC Power Ports 2 kV Line to Ground 1 kV Line to Line 3 IEC 61000 4 5 Surge AC Power Ports 4 kV Line to Ground 2 kV Line to Line 4 Signal Ports 10 V 3 DC Power Ports 10 V 3 AC Power Ports 10 V 3 IEC 61000 4 6 Induced Conducted RFI Earth Ground Ports 10 V 3 IEC 61000 4 8 Magnetic Field Enclosure Ports 40 A m Continuous 1000 A m for 1 s IEC 61000 4 11 Voltage Dips and Interrupts AC Power...

Страница 50: ... Impulse AC Power Ports 5 kV EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RS910W meets Class 2 requirements for an all fiber configuration and Class 1 requirements for copper ports Class 1 allows for temporary communication loss while Class 2 requires error free and interrupted communications Description Test Levels Enclosure Contact 8 kV ESD Enclosure Air 15 kV Radiated RFI Enclosure ...

Страница 51: ...nmental Type Tests Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 Non Condensing 55 C 131 F 6 Cycles IEC 60255 21 1 Vibration 2 g 10 to 150 Hz Class 2 IEC 60255 21 2 Shock 30 g 11 ms Class 2 42 RUGGEDCOM RS910W Installation Manual 04 2021 C7...

Страница 52: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: