Introduction
1.2 Description
Power Supply
• Single 54 VDC, 255 W (or greater) external power supply can deliver 30 W x 8
port per IEEE 802.3at
• Second power supply input for a redundant 54 V power supply
• Complies with IEEE 802.3af, 15 W x 8 output when using 48 VDC power supplies
1.2
Description
The RUGGEDCOM RS900GPF features various ports, controls and indicator LEDs on
the front panel for connecting, configuring and troubleshooting the device.
3
1
4
5
6
2
7
1
Fiber Optic or SFP (Small Form-Factor Pluggable) Ethernet Ports
2
Copper PoE Ethernet Ports
3
POWER LED
4
RS-232 Console Port (DB9)
5
ALARM LED
6
Failsafe Alarm Relay
7
Redundant Power Supply Terminal Blocks
Figure 1.1
RUGGEDCOM RS900GPF
Communication Ports
Receive and transmit network traffic, as well as provide remote Web
access to the RUGGEDCOM RS900GPF operating system. For more
information, refer to:
•
"Connecting to the Device (Page 15)"
•
RS-232 Console Port
The serial console port is for interfacing directly with the device
and accessing initial management functions. For information
about connecting to the device via the serial console port, refer to
"Connecting to the Device (Page 15)"
POWER LED
Illuminates when power is being supplied to the device.