Introduction
1.3 Required Tools and Materials
Color
Description
Green
Device is receiving power
Off
No power
ALARM LED
Illuminates when an alarm condition exists.
Failsafe Alarm Relay
Latches to default state when a power disruption or other alarm
condition occurs. For more information, refer to:
•
"Connecting the Failsafe Alarm Relay (Page 11)"
•
"Failsafe Alarm Relay Specifications (Page 23)"
Power Supply Terminal Block
A pluggable terminal block. For more information, refer to:
•
•
"Power Supply Specifications (Page 23)"
1.3
Required Tools and Materials
The following tools and materials are required to install the RUGGEDCOM RS900GPF:
Tools/Materials
Purpose
DC power cord (16 AWG)
For connecting power to the device.
CAT-5 Ethernet cables
For connecting the device to the network.
#2 Phillips Flathead screwdriver
For mounting the device to a DIN rail.
Phillips screwdriver
For mounting the device to a panel.
4 x M3.5 (#6-32) screws
For mounting the device to a panel.
1.4
Decommissioning and Disposal
Proper decommissioning and disposal of this device is important to prevent malicious
users from obtaining proprietary information and to protect the environment.
Decommissioning
This device may include sensitive, proprietary data. Before taking the device out of
service, either permanently or for maintenance by a third-party, make sure it has
been fully decommissioned.
For more information, refer to the associated
Configuration Manual
.
Recycling and Disposal
For environmentally friendly recycling and disposal of this device and related
accessories, contact a facility certified to dispose of waste electrical and electronic
equipment. Recycling and disposal must be done in accordance with local
regulations.
RUGGEDCOM RS900GPF
Installation Manual, 01/2021, C79000-G8976-1353-05
3