Technical Specifications
5
This section details the specifications and operating conditions of the device.
5.1
Power Supply Specifications
Power
Supply Type
Minimum Input
Maximum Input
Internal
Fuse Rating
Maximum Power
Consumption
12-24 VDC
10 VDC
36 VDC
48 VDC
36 VDC
59 VDC
88 VDC
300 VDC
85 VAC
265 VAC
8 W
(F) denotes fast-acting fuse; (T) denotes time-delay fuse.
This is the same power supply for both AC and DC.
5.2
Failsafe Alarm Relay Specifications
Max Switching
Voltage
30 VAC, 80 VDC, 125 VAC, 250 VAC
Rated Switching
Current
0.3 A @ 30 VAC
1 A @ 30 VDC, 0.3 A @ 80 VDC
0.2 A @ 250 VAC
0.6 A @ 125 VAC
5.3
Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM RS400.
Speed
Connector
Cable
Wiring Standard
Maximum
Distance
Isolation
10/100Base-
TX
RJ45
FDX/HDX > CAT-5
TIA/EIA T568A/B
100 m (328 ft) 1.5 kV
Auto-negotiating.
Shielded or unshielded.
Auto-crossover and auto-polarity.
RMS 1 minute.
RUGGEDCOM RS400
Installation Manual, 01/2021, C79000-G8976-1016-11
27