MODEM MD720 in Terminal Mode
Fehler! Verweisquelle konnte nicht gefunden werden.
27
ATD
Mobile originated Call to dial a number
Executive command
Command:
ATD[<n>]
Response:
The connection cannot be established:
NO DIALTONE
BUSY
NO CARRIER
NO ANSWER
Data connection successfully connected:
CONNECT[<text>]
Parameter:
<n>:
String of dialing digits and optionally V.25ter modifiers (dialing digits): 0-9, * , #, +, A, B, C
Notice:
-
ATE
Local Echo On/Off
Executive command
Command:
ATE[<value>]
Response:
OK
Parameter:
<value>:
0 Local Echo off
1 Local Echo on <Default>
Notice:
This setting determines whether or not the device echoes characters received from
application during command state
ATH
Disconnect existing connection
Executive command
Command:
ATH
Response:
OK
Parameter:
-
Notice:
On this command, all calls in progress are ended.
If a call is in progress, it is necessary to switch into the command phase by +++ before
entering commands.