![Siemens SIMATIC NET FC FO 6GK1900-0RL00-0AA0 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/siemens/simatic-net-fc-fo-6gk1900-0rl00-0aa0/simatic-net-fc-fo-6gk1900-0rl00-0aa0_assembly-instructions-manual_374964014.webp)
Assembly instructions
FC FO LC Plug
13
A5E36312721-AA
7. Position the ø 1.0 mm opening of the stripping
pliers (B) approximately 60 mm from the end of the
wire.
8. Cut into the fiber jacket and pull the jacket off
without skewing.
9. Cut back the Kevlar with the Kevlar scissors (A)
leaving 4 mm.
10. Place the ø 0.3 mm opening of the stripping pliers
(B) on the buffer (blue).
11. Cut into the buffer and pull off the buffer parallel to
the axis of the fiber without skewing.
Note:
It is advisable to pull off the buffer in 2 to 3 steps.
4 mm of the buffer must be left (same length as the
Kevlar).
12. Clean away remnants of the adhesive on the fibers
with alcohol cloths (C).
13. Push the fibers into the LC connector. Make sure
that a part of the Kevlar is pushed into the crimp
opening.
14. Place the LC connector in the crimping pliers (D).