background image

Hardware installation 

 

3.3 Hardware compatibility 

 

CP 5622 

18

 

Operating Instructions, 05/2021, C79000-G8976-C279-04 

Содержание SIMATIC NET CP 5622

Страница 1: ...ATIC NET PG PC PROFIBUS CP 5622 Operating Instructions 05 2021 C79000 G8976 C279 04 Preface Description of the device 1 Software installation 2 Hardware installation 3 Configuration 4 Technical data 5 Approvals A ...

Страница 2: ...perated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Si...

Страница 3: ... Validity of this documentation These operating instructions are valid for the following product CP 5622 Article number 6GK1 562 2AA00 Content of this documentation These operating instructions contain information about the installation and configuration of the CP 5622 communications processor Updated operating instructions on the Internet You will find the current version of these operating instr...

Страница 4: ...ns com cs ww en view 77376110 Volume 2 Interfaces Entry ID 77378184 https support industry siemens com cs ww en view 77378184 The system manuals introduce the topic of industrial communication and explain the communications protocols used There is also a description of the OPC interface as user programming interface Installation manual SIMATIC NET PC Software This document contains detailed inform...

Страница 5: ...sioning through to maintenance and modernization You will find contact data on the Internet at the following address Link https www automation siemens com aspa_app ci yes lang en SITRAIN Training for Industry The training offer includes more than 300 courses on basic topics extended knowledge and special knowledge as well as advanced training for individual sectors available at more than 130 locat...

Страница 6: ... continuous development to make them more secure Siemens strongly recommends performing product updates as soon as they are available and using only the latest product versions Use of product versions that are no longer supported and failure to apply latest updates may increase customer s exposure to cyber threats To stay informed about product updates subscribe to the Siemens Industrial Security ...

Страница 7: ...ics 9 1 2 PROFIBUS interface 11 1 3 Meaning of the LED display 12 2 Software installation 13 2 1 Installing the SIMATIC NET PC Software 13 2 2 Uninstalling the SIMATIC NET PC Software 14 3 Hardware installation 15 3 1 Safety notices 15 3 2 Installing hardware 16 3 3 Hardware compatibility 17 4 Configuration 19 5 Technical data 21 A Approvals 23 ...

Страница 8: ...Table of contents CP 5622 8 Operating Instructions 05 2021 C79000 G8976 C279 04 ...

Страница 9: ... follows Transmission speeds up to 12 Mbps Floating RS 485 connector Linking of up to 32 devices PC PG SIMATIC S7 or ET 200 to form a network segment By linking several segments with repeaters up to 64 nodes can be connected The additional interface signals for a direct link to a PLC Programmable Logic Controller are supported up to 187 5 Kbps Installation in PGs and PCs with a PCI Express slot Th...

Страница 10: ...device 1 1 Product characteristics CP 5622 10 Operating Instructions 05 2021 C79000 G8976 C279 04 Appearance The following graphic shows the CP 5622 communications processor 1 LEDs 2 PROFIBUS interface PB1 master or slave ...

Страница 11: ...ing Input output 1 NC Socket pin 1 is not connected 2 NC M24 Socket pin 2 is not connected With other MPI DP components the return line of the floating 24 V power supply may be via this pin 3 LTG_B Signal line B of the PROFIBUS connector Input output 4 RTSAS RTSAS input signal for direct MPI link The control signal is 1 active when the automation system connected over a special MPI cable is sendin...

Страница 12: ...tion Green off Incorrect bus parameters defective bus e g short circuit or CP not in operation Green flashing fast yellow off Module not started normal status following reset Green and yellow flashing alternately When using more than one module in a PG PC Identification of the module using a diagnostics tool Green and yellow flashing synchro nously Exception state error in firmware Yellow on DP sl...

Страница 13: ... the BIOS of your PG PC Prior to hardware installation Install the software as described in the installation manual SIMATIC NET PC Software You will find this installation manual on the Product Support pages under the following entry ID 77377602 https support industry siemens com cs ww en view 77377602 You should also note the current information on the SIMATIC NET PC software on the Product Suppo...

Страница 14: ... The recommended procedure removes the entire SIMATIC NET PC Software on the PG PC not only the driver for the communications processor Uninstall the entire software package as described and recommended in the installation manual SIMATIC NET PC Software You will find the installation manual on the SIMATIC NET PC Software DVD or on the Product Support pages under the following entry ID 77377602 htt...

Страница 15: ... up components and modules only by their edges Do not touch the pins or conductors Before opening the PG PC make sure that you discharge any electrostatic charge from your body You can do this by touching metal parts on the back panel of the PG PC pulling the power plug Make sure that you also discharge any electrostatic charge from tools you intend to use for the work on the PG PC Do not operate ...

Страница 16: ...he steps outlined below when inserting the communications processor 1 Turn off your PG PC and pull the power cable connector 2 Open the PC housing as described in the manual accompanying your PG PC 3 Remove the cover from a free PCI Express slot 4 Remove the communications processor from its packaging 5 Insert the communications processor in the PCI Express slot and secure it Make sure that the co...

Страница 17: ...there is a PCI Express slot available on the PG PC Note If the previous CP has been removed from the PG PC no configuration changes need to be made You can adopt the configuration of the previous CP To do this you simply need to reload the configuration Note the following When loading the previous configuration the previous CP has priority over the new CP As long as the previous CP is connected it...

Страница 18: ...Hardware installation 3 3 Hardware compatibility CP 5622 18 Operating Instructions 05 2021 C79000 G8976 C279 04 ...

Страница 19: ...STEP 7 Professional TIA Portal Communication Settings COML S7 The steps involved are described in the Commissioning PC Stations manual or in the relevant online helps Compatibility during configuration If there is not yet a CP 5622 in the hardware catalog of your STEP 7 version you can select a CP 5621 or a CP 5611 for configuration The CP 5622 is downwards compatible with the configurations of th...

Страница 20: ...Configuration CP 5622 20 Operating Instructions 05 2021 C79000 G8976 C279 04 ...

Страница 21: ... 3 6 V DC for 3 3 V DC 11 0 13 0 V DC for 12 V DC Properties Safety extra low voltage SELV to EN 60950 Current consumption Typical 300 mA at 3 3 V 250 mA at 12 V Effective power loss Typical 4 0 W Permitted ambient conditions Operating conditions Temperature EN 60068 2 1 2 Temperature change max 5 to 50 C 10 K h Relative humidity EN 60068 2 78 85 at 30 C no condensation Rapid temperature change EN...

Страница 22: ...d Weight 87 g Dimensions W x H x D in mm 18 x 107 x 101 Electromagnetic compatibility Emission to EN 55022 to FCC Class B Class B Immunity On signal cables Surge to EN 610004 5 Burst to EN 61000 4 3 2 kV 2 kV to discharge of static electricity Contact discharge to IEC 61000 4 2 6 kV to radiated radio frequencies to EN 61000 4 3 10 V m at 80 MHz to 2 GHz 10 V m 50 on load factor at 900 MHz and 1 89...

Страница 23: ...mall businesses EN 61000 6 3 EN 61000 6 1 Industrial environment EN 61000 6 4 EN 61000 6 2 RoHS Directive The product meets the requirements of the EC directive 2011 65 EU RoHS Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment Applied standard EU L174 01 07 2011 Declaration of conformity You will find the declaration of conformity for th...

Страница 24: ...ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Siemens AG is not responsible for any radio television interference caused by una...

Отзывы: