Technical Specifications
45
CP 5512 Installation Instructions/Product Information
A5E00175148-02
Noise immunity
Electromagnetic HF field, ampli-
tude modulated complying with
EN 61000 / IEC 1000-4-3
80 to 2000 MHz 10V/m 80% AM
900 MHz, 1.89 GHz 10 V/m 50%
PM
High-frequency sinusoidal com-
plying with IEC 61000-4-6/
EN6100-4-6
9 KHz to 80 MHz 10 V 80 % AM
Power supply cable, LAN cable,
ground connection
Discharge of static electricity
complying with EN 61000-4-2 /
IEC 61000-4-2 (ESD)
±
6 kV contact discharge
±
6 kV air discharge
Fast transients complying with
EN 61000-4-4 / IEC 61000-4-4
(burst)
±
2kV
µ
s pulses complying with IEC
61000-4-5 (surge)
±
2kV