Application
5.1 Program
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02
37
Table 5- 19 Relationships and dependencies of the parameters
Parameter
Dependency
Description
Auto-trigger, Scan
Options > Extras
"Auto trigger" and "Scan" are not possible when "Use" is
enabled for the program sequence.
5.1.3.5
E-focus
You can make the manual E-focus settings in this group.
Table 5- 20 E-focus
Parameter
Possible values
Default
Description
Relative operat-
ing distance
10.00 ... 100.00%
15,00 %
When you use an Electro-Focus lens (EF lens), you can use
this parameter to manually set the working distance between
the camera and the object it has to read. The greater the
object distance, the higher the value specified here must be.
The automatic determination can be started via the "Auto-
setup" group. The value set depends, among other things, on
the screw-in depth of the lens and the LED color.
5.1.3.6
Verification
Select a calibration from the verification library in the reference drop-down list. This way, you
preset the exposure options for image acquisition and define the code verification standard
for the decoder steps in the program.
Note
Verification
For verification, you need the Veri-Genius license.