Installation of the TCP1  

 

Step 1:

  Remove face cover # 80887A (#10 below) 

 

Step 2: 

Attached TCP1 with same screws from face cover (#below).  Tighten securely 

into place.   
Note: position the TCP1 so that the air cylinder is on the left hand side of the sewing 
head. 
 

Step 3:

  Attach air filter/regulator where best suited for operation.  Make sure that the 

tubing is NOT pinched and clear of moving parts. 
 

Step 4:

 You will need to supply air and fittings for filter/regulator with ¼” port size NPT 

with following specs:  Max air pressure: 150 psi, 125 deg F, 18 cfm air supply 
 

Step 5:

  Once system is installed, adjust pressure on regulator by turning the dial.  

Counter clockwise rotation to decrease pressure, clockwise to increase. 

Set at 40-60 psi 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 