Installing and connecting the device
3.3 Connecting the device
Mobile Client900WXN
Operating Instructions, 04/2015, A5E35883103-AB
37
3.3
Connecting the device
3.3.1
Connecting the connection box
3.3.1.1
Overview
NOTICE
Approved connecting cables
Only the following connecting cables may be connected to the Connection Box
compact CA:
•
6AV6645-7CY03-1WP0 (FS02), 5 m long
•
6AV6645-7CY04-1WP0 (FS02), 10 m long
•
6AV6645-7CY05-1WP0 (FS02), 15 m long
Note
Installation notes and instructions on use
•
The Connection Box compact CA is only suitable for installation in a control cabinet.
Please observe the relevant guidelines for control cabinet construction at the place of
use.
•
Make sure that all the connectors and cables have sufficient contact and strain relief.
•
The two LEDs at the RJ45 socket are not supported by the hardware and are not
illuminated during operation.
Requirement
●
The connection box is mounted in accordance with the specifications of these operating
instructions.
●
Only shielded standard cables may be used.
Note
Permitted length of the connecting cable
Do not exceed the permitted cable length. Otherwise, functional errors may occur.
Observe the maximum length for the connecting cable. This information concerns the
length of the cable between the connection box and the HMI device.
Содержание SIMATIC Mobile Client900WXN
Страница 8: ...Table of contents Mobile Client900WXN 8 Operating Instructions 04 2015 A5E35883103 AB ...
Страница 28: ...Safety guidelines 2 2 Notes about usage Mobile Client900WXN 28 Operating Instructions 04 2015 A5E35883103 AB ...
Страница 88: ...Abbreviations B 1 Abbreviations Mobile Client900WXN 88 Operating Instructions 04 2015 A5E35883103 AB ...
Страница 90: ...Glossary Mobile Client900WXN 90 Operating Instructions 04 2015 A5E35883103 AB ...
Страница 94: ...Index Mobile Client900WXN 94 Operating Instructions 04 2015 A5E35883103 AB ...