![Siemens SIMATIC ITP1000 Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/siemens/simatic-itp1000/simatic-itp1000_operating-instructions-manual_378656095.webp)
Technical specifications
6.7 Active Management Technology (AMT)
SIMATIC ITP1000
Operating Instructions, 05/2017, A5E37340160-AB
95
6.6.8
Alarm, error and system messages
During startup (the boot process), the BIOS first performs a Power On Self Test (POST) and
checks whether certain functional units of the PC are operating error-free. The boot
sequence is immediately interrupted if critical errors occur.
BIOS initializes and tests further functional units if the POST does not return any errors. In
this startup phase, the graphics controller is initialized and any error messages are output to
the screen.
The error messages output by system BIOS are listed below. For information on error
messages output by the operating system or application programs, refer to the
corresponding manuals.
On-screen error messages
On-screen error message
Meaning / tip
Operating system not found
Possible causes:
•
No operating system installed
•
Incorrect active boot partition
•
Wrong boot drive settings in SETUP
Keyboard controller error
Controller error.
Contact your technical support team.
SMART failure detected on HDD
Hard disk reports pending failure through
S.M.A.R.T.
CMOS battery failed
CMOS battery is not connected.
CMOS battery weak
CMOS battery is weak
Real-time clock has lost power
The CMOS clock was operated without battery or
with a battery that was too weak, during battery
change, for example. Check the CMOS clock.
Keyboard error
Function keys are defective
PLD configuration failed
Programming of the PLC on the motherboard
has failed.
Содержание SIMATIC ITP1000
Страница 4: ...Preface SIMATIC ITP1000 4 Operating Instructions 05 2017 A5E37340160 AB ...
Страница 22: ...Overview 1 4 Accessories SIMATIC ITP1000 22 Operating Instructions 05 2017 A5E37340160 AB ...
Страница 104: ...Technical Support A 2 Troubleshooting SIMATIC ITP1000 104 Operating Instructions 05 2017 A5E37340160 AB ...
Страница 108: ...Labels and symbols B 5 Interfaces SIMATIC ITP1000 108 Operating Instructions 05 2017 A5E37340160 AB ...