Overview
1.3 Accessories
SIMATIC IPC677D
Operating Instructions, 09/2014, A5E32995420-AC
17
1.2.3
PROFINET status displays
PROFINET status display
Display
Meaning
LED
Description
①
SF
PROFINET,
optional
Status display for
CP 1616 onboard
OFF
•
CP not available
•
CP disabled
•
No error, communication
established
•
Download in progress
Slow flashing
•
Link status error
•
IO controller: IO device cannot
be addressed
•
IO controller: Duplicate IP
address
Fast flashing
Exception error: Diagnostics via
Web or SNMP no longer possible
AN
•
Diagnostic information
available
•
No communication
established.
Virtual status displays
The two "virtual" CP 1616 LEDs can only be seen in the SIMATIC software and can be scanned via
SNMP.
PROFINET
Virtual LEDs
RUN
CP is active
STOP
CP is in the stop state
Flashes
There are no "slow flashing" or
"fast flashing" states.