Technical specifications
8.5 Hardware description
SIMATIC IPC647D
Operating Instructions, 01/2014, A5E32996306-AA
161
I/O address
(hex)
Size
[byte]
Description of the basic function
Alternative function
From
To
02E8
02EF
8
<Reserved>
Reserved for COM1 or COM2
02F0
02F7
8
<Not used>
02F8
02FF
8
COM2
Can be deactivated in setup, then
free
Reserved for COM1 or COM2
0300
0377
120 <Not used>
0378
037F
8
LPT1
Can be deactivated in setup, then
free
Reserved for LPT1
0380
03AF
48
<Not used>
03B0
03BB
12
Graphics
03BC
03BF
4
<Reserved>
03C0
03DF
32
Graphics
03E0
03E7
8
<Not used>
03E8
03EF
8
<Reserved>
Reserved for COM1 or COM2
03F0
03F7
8
<Not used>
03F8
03FF
8
COM1
Can be deactivated in setup, then
free
Reserved for COM1 or COM2
Dynamic range – resources are managed by means of Plug and Play functionality
I/O address
(hex)
Size
[byte]
Description of the basic function
Alternative function
From
To
0400
0453
84
Motherboard resources
04D0
04D1
2
Programmable interrupt controller
0680
069F
32
Motherboard resources
0800
087F
128 Motherboard resources
164E
164F
2
Motherboard resources
1800
18FE
255 Motherboard resources
1854
1857
4
Motherboard resources
Cascaded
2004
2007
4
Motherboard resources
FFFF
FFFF
1
Motherboard resources
Содержание SIMATIC IPC647D
Страница 4: ...Preface SIMATIC IPC647D 4 Operating Instructions 01 2014 A5E32996306 AA ...
Страница 28: ...Safety Instructions 2 2 Notes on use SIMATIC IPC647D 28 Operating Instructions 01 2014 A5E32996306 AA ...
Страница 214: ...Glossary SIMATIC IPC647D 214 Operating Instructions 01 2014 A5E32996306 AA ...
Страница 220: ...Index SIMATIC IPC647D 220 Operating Instructions 01 2014 A5E32996306 AA ...