![Siemens SIMATIC IPC627D Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/siemens/simatic-ipc627d/simatic-ipc627d_operating-instructions-manual_378272027.webp)
Installing and connecting the device
3.1 Preparing for installation
SIMATIC IPC627D/827D
Operating Instructions, 09/2014, A5E32990859-AB
27
An inclination of ± 20° is permitted for all approved mounting positions.
Position 1 (preferred) for
wall mounting: The
interfaces are at the right.
Position 2 for wall mounting:
The interfaces are at the left.
Position 3 (desktop)
Additional mounting positions according to UL508/CSA 22.2 No. 142
An inclination of ±15° is allowed in this mounting position.
Position 4 (interfaces facing down)
CD/DVD drive may not be operated.
Position 5 (interfaces facing up)
CD/DVD drive may not be operated.
NOTICE
Points to note for position 4 and 5
CD/DVD and floppy drives cannot be operated in this position. The CD drawer opens
upward or downward, which can lead to mechanical damage in the drawer mechanism.
Note
Mounting positions 4 and 5 are also permitted for the Information Technology Equipment
area when the device is mounted in an enclosure that fulfills the requirements stipulated by
sections 4.6 and 4.7.3 of IEC/UL/EN/DIN EN 60950-1.