Operating the device
5.3 Drive configurations
76
Operating Instructions, 01/2021, A5E43920357-AA
5.3
Drive configurations
5.3.1
RAID systems
5.3.1.1
RAID1 system
An RAID1 system works on the principle of "data mirroring on two drives".
In the event of a defective drive the RAID1 system can continue to work on the remaining
drive and thus achieves a high level of availability.
RAID1 system with associated software
If you have ordered a RAID1 system with pre-installed operating system, the RAID1 system is
monitored with the installed diagnostics software SIMATIC IPC DiagBase or DiagMonitor.
The following software is available to monitor the RAID1 system:
•
Onboard RAID system (Page 78):
Intel® Rapid Storage Technology
See also
Install drives on the drive bay plate (Page 125)
Drive cage type A (Page 18)
5.3.1.2
RAID5 system
A RAID5 system works according to the "stripping with parity" principle.
In the event of a defective drive or cable problems the RAID5 system can continue to work on
the remaining drives and thus achieves a high level of availability.
RAID5 system with associated software
If you have ordered a RAID5 system with pre-installed operating system, the RAID5 system is
monitored with the installed diagnostics software SIMATIC IPC DiagBase or DiagMonitor.
The following software is available to monitor the RAID5 system:
•
Onboard RAID system (Page 78):
Intel® Rapid Storage Technology
See also
Drive cage type A (Page 18)
Install drives on the drive bay plate (Page 125)
Содержание SIMATIC IPC547J
Страница 10: ...Table of contents 10 Operating Instructions 01 2021 A5E43920357 AA ...
Страница 74: ...Commissioning the device 4 3 Switching off the device 74 Operating Instructions 01 2021 A5E43920357 AA ...
Страница 166: ......
Страница 170: ......
Страница 192: ...Markings and symbols C 5 Interfaces 192 Operating Instructions 01 2021 A5E43920357 AA ...