Technical support
A.2 Problem solving
SIMATIC IPC547D
Operating Instructions, 06/2011, A5E03473780-01
115
A.2.3
Using modules of third-party manufacturers
Problem
Possible cause
To correct or avoid error
Check your computer configuration:
If the computer configuration corresponds to the delivery
state, contact your technical support team.
In the case of a change in the configuration, restore the
delivery state. To do this, remove the third-party modules
and restart the device. If the error no longer occurs, the
third-party module being used was the cause of the fault.
Replace the thrid-party module with a Siemens module or
contact the module supplier.
Redundant I/O addresses
Redundant hardware interrupts
and/or DMA channels
Fluctuation of signal frequencies
or levels
Different pin assignment
If the device still crashes, contact your technical support team.
The device
crashes during
startup
Insufficient output of an external
power supply, e.g. UPS
Use a higher capacity power supply
The device does
not start up or
switches off
immediately
A counter voltage is fed into the
device by connected or installed
third-party components
Clarify the following with the supplier of the component:
The component can be operated without an external power
supply.
The component can be reconfigured so that it only uses the
external power supply or that of the device.
so that only the PC voltage supply or external voltage supply
is used"