Commissioning the device
4.3 Switching off the device
SIMATIC IPC347E
Operating Instructions, 09/2018, A5E41134132-AE
39
Fully disconnecting the device from mains voltage
WARNING
Risk of fire and electric shock
The on/off button and on/off switch do not fully disconnect the device from the mains. If the
device is switched off with the on/off switch, there remains a risk of electric shock and fire
hazard, for example, if the device or connection cables are damaged or if the device is
used improperly.
Always fully disconnect the device from the mains voltage as described below before
performing work on the device or when the device will not be used over an extended period
of time.
If the device was not mounted in a control cabinet:
●
Shut down the operating system and pull the power plug on the rear of the device.
If the device was mounted in a control cabinet:
●
Shut down the operating system and switch the AC circuit breaker to "Off".
The device is switched off and fully disconnected from the mains voltage. No trickle current
is flowing.
Hardware reset
You can perform a hardware reset to switch off the device when the operating system no
longer responds to input from the keyboard or mouse. The operating system is not safely
shut down in this case.
NOTICE
Risk of data loss
The device is restarted in the case of a hardware reset. Data in the main memory can be
deleted. Data on the drive may be lost. The device may be damaged.
Perform a hardware reset only in the case of an emergency.
For all operating systems:
●
Press the on/off button for more than four seconds.
Содержание SIMATIC IPC347E
Страница 8: ...Table of contents SIMATIC IPC347E 8 Operating Instructions 09 2018 A5E41134132 AE ...
Страница 24: ...Safety instructions 2 4 Notes on use SIMATIC IPC347E 24 Operating Instructions 09 2018 A5E41134132 AE ...
Страница 82: ...Technical specifications 7 5 BIOS description SIMATIC IPC347E 82 Operating Instructions 09 2018 A5E41134132 AE ...
Страница 100: ...Appendix Motherboard A 4 Installing drivers SIMATIC IPC347E 100 Operating Instructions 09 2018 A5E41134132 AE ...
Страница 126: ...Appendix Technical support D 2 Problem solving SIMATIC IPC347E 126 Operating Instructions 09 2018 A5E41134132 AE ...
Страница 132: ...Appendix List of abbreviations SIMATIC IPC347E 132 Operating Instructions 09 2018 A5E41134132 AE ...
Страница 148: ...Index SIMATIC IPC347E 148 Operating Instructions 09 2018 A5E41134132 AE ...