Technical specifications
8.4 Technical specifications
SIMATIC IPC1047
108
Operating Instructions, 09/2018, A5E45118479-AA
Electromagnetic compatibility (EMC)
Radiated interference
EN 61000-6-3, FCC Class A
EN 61000-6-4;
CISPR 22 / EN 55022 Class A
EN 61000-3-2 class D, EN 61000-3-3
Noise immunity: Conducted
disturbance variables on supply lines
± 2 kV, according to IEC 61000-4-4, burst
± 2 kV, according to IEC 61000-4-5, surge sym.
± 2 kV, according to IEC 61000-4-5, surge asym.
Noise immunity on signal lines
± 2 kV, according to IEC 61000-4-4; burst; length < 30 m
± 2 kV, according to IEC 61000-4-4; burst; length > 30 m
± 2 kV; according to IEC 61000-4-5; surge; length > 30 m
Immunity to discharge of static
electricity
± 4 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
Immunity to RF interference
•
10 V/m, 80...1000 MHz and 1.4...2 GHz,
80% AM 1 kHz, according to IEC 61000-4-3
•
3 V/m 2...6 GHz, 80% AM 1 kHz,
according to IEC 61000-4-3
•
10 V, 15 KHz...80 MHz, 80% AM 1 kHz,
according to IEC 61000-4-6
Magnetic field
100 A/m, 50 Hz/60 Hz, according to IEC 61000-4-8
Climatic ambient conditions
Temperature
Tested in accordance with IEC 60068-2-2, IEC 60068-2-1, IEC 60068-2-14
During operation
0 °C … +50° C in basic configuration
0 °C … +40 °C in maximum configuration
For more detailed information, see section "Retrofitting instructions
(Page 51)".
Storage/transport
Gradient
–20 °C … +60 °C
≤ 20°K/h, no condensation
Relative humidity
Tested in accordance with IEC 60068-2-78, IEC 60068-2-30
During operation
Gradient
5% to 85% at 30 °C, no condensation
≤ 10°K/h, no condensation
Storage/transportation,
Gradient
5% … 95% at 25 °C to 55 °C, no condensation
≤ 20
K/h, no condensation
Atmospheric pressure
Tested according to DIN IEC 60950-1
During operation
1080 … 689 hPa,
corresponds to an elevation of –1000 to 3000 m
Storage/transport
1080 … 660 hPa,
corresponds to an elevation of -1000 to 3500 m